SPECIFICATIONS
Installation Requirements
The oven can be installed in a standard or flush inset
application. If a cooktop is being installed above the oven,
a minimum of 6 mm is required between units. Location of
the electrical supply within the oven opening may require
additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
ICBSO24TE
ICBSO2418TE
TRIM OVERLAP
Top
Bottom
Sides
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
MIN
68 kg
The electrical supply must be placed in an adjacent cabinet
45 kg
within reach of the 1.8 m power cord. Locate the electrical
supply as shown in the illustrations on the following pages.
6 mm
A separate circuit, servicing only this appliance is required.
0 mm
A ground fault circuit interrupter (GFCI) is not recommended
17 mm
and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Power Cord
RATING PLATE
Rating plate location.
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
220-240 VAC, 50 Hz
3400 Watts
1.8 m
|
wolfappliance.com