hestan KGC 30 Manuel D'installation page 13

Masquer les pouces Voir aussi pour KGC 30:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GAS COOKTOP OPERATION
BURNER FLAMES
Turn each burner on. For Natural Gas installations, the flames should be blue in color with no trace
of yellow. With LP, the tips of the flame may be yellow.
The burner flames should not flutter or lift off from the burner ports. The inner cone of the flame
should be between 1/2" and 3/4" long.
SEALED SURFACE BURNERS
IMPORTANT: Do not obstruct the flow of combustion and ventilation air around the burner grate
edges.
Burner cap and gas spreader
Always keep the burner cap and gas spreader in place when using a surface burner. A
clean burner cap and spreader will help prevent poor ignition and uneven flames. Always
clean the part after a spillover and routinely remove and clean according to the "Care and
Maintenance" section.
Burner base and orifice
Gas must flow freely through the orifice to light properly. Keep this area free of soil and
do not allow spills, food, cleaning agents or any other material to enter the orifice or the
area around it.
Protect it during cleaning.
BE SURE WHEN LIGHTING THE BURNER:
Gas spreader pin is properly aligned with burner base slot.
Cap pin is properly aligned with gas spreader slot.
BURNERS AND BURNER PORTS
Check burner flames occasionally. Observe figure 5 below - with Natural Gas, a good flame is blue
in color, not yellow. With LP, the tips of the flame may be yellow.
Keep this area free of soil and do not allow spills, food, cleaning agents or any other material to
enter the burner ports.
Figure 5.
Burner flame
appearance
(CONTINUED)
COOKTOP BURNER
Burner flame size
Figure 6.
©2018 Hestan Commercial Corporation
1/2" to 3/4"
11
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Kgc 36

Table des Matières