9.2 Appliance-specific information: Kalle

9.2.1 Outside air connection, air slide and flue gas exhaust

9.2.1.1 Outside air connection

The fire is made with an outside air connection. This outside air connection is provided separately (see appendix 2,
fig. 16-2). Assembly always takes place at the bottom of the appliance.
When mounting the outside air connection, please proceed as follows (see appendix 2, fig. 4 and 16):
Ø
Remove the guard plate (see appendix 2, fig. 16-1).
Ø
Unscrew the 4 pre-assembled bolts (see appendix 2, fig. 16-2).
Ø
Place the outside air connection against the plate on the bottom of the appliance.
Ø
Then re-tighten the 4 bolts.
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe opening' of the outside air connection. The flexible hose
can be fed both from the back and the bottom. For this purpose, the round plate at the back or bottom of the
appliance must be pressed out (see appendix 2, fig. 4).
Ø
Place back the guard plate.

9.2.1.2 Air slide

When installing and maintaining the appliance, check the operation of the air slide (see appendix 2, fig. 17).
It is possible that steel grit ended up in the air slide during transportation. If the air slide does not run smoothly, it
has to be cleaned. For this, the air slide should be disassembled. The air slide valve is suspended by means of a nut
and a spring.
When disassembling the air slide, proceed as follows (see appendix 2, fig. 17):
Ø
Remove the guard plate (see appendix 2, fig. 16-1).
If an outside air connection is mounted, it should be removed first. For this, observe the instructions in section
!Caution
9.2.1.1 (see appendix 2, fig. 16-2).
Ø
Unscrew the nut at the bottom of the air slide.
As soon as the nut has been loosened, the air slide and accessory will drop down. Make sure you catch the
!Caution
accessory!
Ø
Check the air slide valve and clean it if necessary.
For placing back the air slide, the actions described for disassembling should be performed in reverse order.

9.2.1.3 Flue exhaust

The flue exhaust has a 150 mm diameter connection and can be connected to the conical exhaust ring in two
ways: dewatering and non-dewatering.
Here, you should use the correct connection pieces.
In case of a dewatering connection, different connection pieces are used than in case of a non-dewatering
!Caution
connection.
The required connection pieces are available via your supplier.
The flue exhaust can also be connected at the top or rear of the appliance.
In case of a connection at the rear, please proceed as follows:
Ø
Remove the cover plate on top of the appliance.
Ø
Remove the flame baffle plate (see section 9.2.2.2).
Ø
Unscrew the 3 nuts from the exhaust ring mounted at the top of the appliance.
Ø
Unscrew the nuts from the plate at the rear of the appliance.
A disc has to be hammered out of the rear of the appliance, after this plate has been removed (see appendix 2, fig.
!Caution
2).
Ø
Mount the plate that you unscrewed from the rear of the appliance at the top of the appliance on the place where
the exhaust ring used to be.
For a clean finish, you will be able to obtain a special, closed top plate via your supplier.
!Tip
Ø
Mount the exhaust ring at the rear of the appliance by tightening the 3 bolts.
Ø
Place back the flame baffle plate (see section 9.2.2.2).