Commissioning; Installation Location; Connection To Mains Power Supply/ Extension Cable 39 6.2 Initial Starting-Up; Initial Starting-Up - Titan PowrPlast 600 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PowrPlast 600
6

cOMMISSIONING

6.1

INStALLAtION LOcAtION

The mortar spraying machine and the bucket from which the
material to be processed is to be pumped have to be set up on
an even and firm underground. This ensures that the machine
and bucket cannot slide away or fall over.
6.1.1
cONNectION tO MAINS POWeR SuPPLy/
exteNSION cABLe
connection to the mains network only via a special feed-
ing point, for example via a distribution board for con-
struction sites, with residual current protective device
with INF ≤ 30 mA.
Lay the device supply cable so that there is no
danger of stumbling.
Protect against damage, for example against
being driven over.
Min. wire cross-section 3 x 1.5 mm
extension cable completely. Ensure that the
coupling pieces and plugs are free of dam-
age.
• Before connecting the unit to the mains supply, ensure that
the line voltage matches that specified on the rating plate.
6.2

INItIAL StARtING-uP

6.2.1

ScOPe OF SuPPLy

The machine is supplied by the manufacturer in the following
individual components:
• Complete basic machine comprising drive unit, control unit
and transport frame with wheels
• Pump unit complete
• Tool : Special key
• Hose package
• Spray lance
• Pump sliding means
6.2.2

ASSeMBLy

Pull safety pin (1) to rear to release lock. Pull PowrPlast 600 up
by its frame (2) until the machine engages in the top position.
Spray rotor (3) with a suitable pump lubricant (order no. 9992
824).
Move selector switch (4) to "A" and set delivery volume con-
troller (5) to „0".
Connect mains plug to mains power supply.
The operation light (6) shows operational readiness.
Fold locking pins (7) up towards the magnet holders in the
handle to prevent them being twisted during assembly.
Slide pump unit (8) over rotor (3) from below and press up-
wards.
Set delivery volume controller (5) to 1 or 2.
Set selector switch (4) to "F" to switch on pump. The pump unit
is automatically drawn up by the rotor.
As soon as the pump unit is in its end position, fold the two
locking pins (7) down and use nuts to fix the pump unit.
. Unroll the
2
Set selector switch (4) to "A" to switch off pump.
Disconnect mains plug.
4
5
Only the person controlling the machine
may assemble the pump unit.
Never operate mortar spraying machine
with an exposed rotor.
Do not reach into the rotor when it is
moving. Risk of crushing.
caution if you have long hair. Only wear
close-fitting clothes at work.
If necessary rotate pump unit (8) by hand to
move locking pins (7) into end position.
After assembling the pump unit, secure the
union nut (9) on the pump unit, using the
special key to do so.