6. Specifications

MODEL
CAPACITY*
INPUT
Low Line Transfer
Voltage
Low Line Comeback
Range
High Line Transfer
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Output voltage
AC Voltage Regulation
(Batt. Mode)
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)
Overload
Current Crest Ratio
Harmonic Distortion
AC Mode to Batt. Mode
Transfer
Time
Inverter to Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Numbers
Standard
Recharge Time
Model
Charging Current
Charging Voltage
Battery Type & Numbers
Long-run
Charging Current
Model
Charging Voltage
PHYSICAL
Dimension, D X W X H
Standard
Model
Net Weight (kgs)
Dimension, D X W X H
Long-run
Model
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
* Reduce capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC. **Product
specifications are subject to change without further notice. Low voltage (110V) and High Voltage (220V) models are different products.
INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com
41
Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – hotline@infosec.fr – 08 14 AA XX 203 05
E4 LCD Pro 1000 (S) E4 LCD Pro 1500 (S) E4 LCD Pro 2000 (S) E4 LCD Pro 3000 (S)
1000 VA / 900 W
1500 VA / 1350 W
90VAC/80VAC/70VAC/60VAC±5% or 180VAC/160VAC/140VAC/120VAC±5%
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
100VAC/90VAC/80VAC/70VAC or195VAC/175VAC/155VAC/135VAC ± 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
≧ 0.99 @ 220-230 VAC (input voltage)
110/115/120/127VAC or 208/220/230/240VAC
47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass
110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when
>130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the
≦ 3 % THD (linear load); ≦ 6 % THD (non-linear load)
88%
83%
2
4 hours recover to 90% capacity (Typical)
27.4 VDC ± 1%
2
3
27.4 VDC
41.0VDC ±
54.7 VDC
± 1%
1%
282 X 145 X 220 (mm)
9.8
282 x 145 x 220 (mm)
4.1
4.1
20-90 % RH @ 0- 40°C (non-condensing)
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Power management from SNMP manager and web browser
2000 VA / 1800 W
0
(Ambient Temp.<35
0
(Ambient Temp.<35
145 VAC ± 5 % or 300 VAC ± 5 %
140 VAC ± 5 % or 290 VAC ± 5 %
40Hz ~ 70 Hz
Single phase with ground
±1% (Batt. Mode)
50 Hz ± 0.5% or 60Hz ± 0.5%
when the utility is normal
the utility is normal
utility is normal
3:1
Zero
4 ms (Typical)
Pure Sinewave
89%
87%
12V / 9Ah
4
1A (max.)
54.7 VDC ±1%
4
6
1A/2A/4A/6A
109.4VDC
82.1VDC ±1%
±1%
397 X 145 X 220 (mm)
17
397x 145 x 220(mm)
6.8
6.8
Less than 50dBA @ 1 Meter
3000 VA / 2700 W
C)
C)
90%
88%
6
82.1 VDC ±1%
8
6
82.1 VDC
109.4VDC
±1%
±1%
421 X 190 X 318 (mm)
27.6
6.8
7.4
8
±1%
7.4