EXPERT GRILL GBT1826WRS-C Manuel Du Propriétaire page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

16
Problem
Burner will not light using
igniter
(if included)
Burner will not light with
match
Sudden drop in gas flow or
reduced flame height
Irregular flame pattern –
flame does not run the full
length of burner
Flame is yellow or orange
Flame goes out
Flare-up
Persistent grease fire
Flashback (fire in burner
tube(s))
Inside of lid is peeling (like
paint peeling)
Troubleshooting
Possible Cause
LP gas tank is low or empty
LP gas leak
Wires or electrode covered with cooking residue
Electrode and burners are wet
Electrode cracked or broken - sparks at crack
Wire loose or disconnected
Wire is shorting (sparking) between igniter and
electrode
Bad igniter
No gas flow
LP gas tank is low or empty
LP gas leak
Coupling nut and regulator not fully connected
Obstruction of gas flow
Spider webs or insect nest in venturi
Burner ports clogged or blocked
Out of gas
Burner ports are clogged or blocked
New burner may have residual manufacturing
oils
Spider webs or insect nest in burner/venturi tube Clean burner/venturi tube
Food residue, grease, etc . on burners
Poor alignment of valve to burner/venturi tube
High or gusting winds
Low on LP gas
Overflow valve tripped
Grease buildup
Excess fat in meat
Excessive cooking temperature
Grease trapped by food buildup around burner
system
Burner and/or burner tubes are blocked
Baked on grease buildup has turned to carbon
and is flaking off .
Prevention/Cure
Replace LP gas tank
1 .
Turn LP gas tank valve to " OFF"
2 .
Wait 5 minutes for gas to clear
3 .
Follow "Checking for Leaks" section
Clean wire and/or electrode with rubbing alcohol
Wipe dry with cloth
Replacement part(s) may be needed - contact Customer
Care at 1 .800 .694 .0013
Reconnect wire or replacement part(s) may be needed -
contact Customer Care at 1 .800 .694 .0013
Replacement part(s) may be needed - contact Customer
Care at 1 .800 .694 .0013
Replacement part(s) may be needed - contact Customer
Care at 1 .800 .694 .0013
Check if LP gas tank is empty
A . If empty, replace
B . If LP gas tank is not empty, refer to "Sudden drop in
gas flow or reduced flame height" below
Replace LP gas tank
1 .
Turn LP gas tank valve to " OFF"
2 .
Wait 5 minutes for gas to clear
3 .
Follow "Checking for Leaks" section
Turning the coupling nut about one-half to three-quarters
additional turn until solid stop . Tighten by hand only – do
NOT use tools.
Clear burner/venturi tube
Clean burner/venturi tube
Clean burner ports
Replace LP gas tank
Clean burner ports
Operate grill for 15 minutes on (HIGH) with the lid closed
Clean burner
Ensure burner/venturi tube is properly engaged with valve
Do not use grill in high winds
Replace LP gas tank
Refer to "Sudden drop in gas flow or reduced flame height,"
above
Remove and clean all grill parts per "Cleaning and Care"
section
Trim fat from meat before grilling
Adjust (lower) cooking temperature
1 . Turn control knob to " OFF"
2 . Leave lid in closed position and let fire burn out
3 . After grill cools, remove and clean all grill parts per
"Cleaning and Care" section
Clean burner and/or burner/venturi tube
Clean all grill parts per "Cleaning and Care" section .

Publicité