J: When the FUEL
indicator has appeard,
the information display
will show the number of
minutes of fuel left in
the tank.
K: A blinking VENT
indicator is a sign
that you need extra
ventilation.
Fuel filter
L
p062_073_SRE231E_uk.indd 69
Without the 'SAVE' setting your heater will maintain the set temperature by
approximation as well, by adjusting its heating capacity. 'SAVE' is an economy
setting, which you can use when, for instance, you are not present in the room
or to keep it frost-free.
K

THE 'FuEL' INDICATOR

When the FUEL indicator appears, it means that there is only fuel left for 10
more minutes. The count-down of the remaining heating time can be seen in the
information display K (Fig. J). Now you have two options:
e
you remove the fuel tank and refill it outside the living room (section B) or
e
you push the button extension S. By pushing this button, the remaining
heating time will extend to 60 minutes.
The heater will automatically switch back to its lowest position. In the display
the number 60 will appear, which will decline to 10. At the arrival of 10,
you will hear an alarm signal every two minutes, warning you to refill the
removable tank. If you do not react, the heater will extinguish by itself. The
heater will also sound a warning signal, when it switches off. The fuel
indicator will blink, while four lines (--:--) are blinking in the information
display. You can stop this by pressing the
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L
THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, an intermittent buzzer will
be heard (approximately once each 30 seconds) and the VENT indicator will be
lit. When this signal is given, ensure that the ventilation of the room is improved
(e.g. by opening a door or window a little more), to avoid that the heater shuts
off. When the ventilation of the room is improved, the VENT indicator and buzzer
will be deactivated. When there is still insufficient ventilation, the heater shuts off
automatically. When this occurs, e -1 1 is displayed and the VENT indicator is blinking.
After improving the ventilation of the room (e.g. by opening a door or window a
little more), the heater can be ignited by pushing the
M
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your heater needs hardly any
maintenance. It is, however, important that you clean the vent filter 8 with a
vacuum cleaner and the grid 2 with a damp cloth, both on a weekly basis.
Regularly inspect the fuel filter as well:
1
Remove the removable tank 6 from the heater and remove the fuel filter
(Fig. L). Some drops may leak from the filter; keep a cloth at hand.
2
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(never clean it with water!)
3
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains from time to time with a damp
cloth, because otherwise these may cause stains that are hard to remove.
button L once more.
button L again.