Warranty Provisions - Zibro SRE 231 E Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
p062_073_SRE231E_uk.indd 71
P
SPECIFICATIONS
Ignition
Fuel
Capacity (kW) max.
Capacity (kW) min.
Suitable space (m
)
3
**
Fuel consumption (l/hr)
Fuel consumption (g/hr)
Burning time per tank (hr)
Capacity removable tank (litres) 5.4
Weight (kg)
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
* At maximum setting ** Specified values are indicative
Q

WARRANTy PROVISIONS

Your heater comes with a 48-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
1
We expressly dismiss all other claims for damages, including consequential
damages.
2
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
3
The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
4
The warranty shall not apply to parts that are subject to normal wear, such as
the burner mat and the manual fuel pump.
5
The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
6
The warranty shall not apply to damages caused by actions not in compliance
with the Directions for Use, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.
7
Transportation costs and the risks involved during the transportation of the
heater or heater components shall always be at the expense of the purchaser.
In order to avoid unnecessary costs, we recommend that you always read the
'Directions for Use' carefully first. In case they offer no solution, please take the
heater to your dealer for repair.
* Highly inflammable substances may induce uncontrollable burning, causing flames to break out. Should this
happen, never try to move the heater, but always switch off the heater immediately. In case of emergency you
may use a fire extinguisher, but only a type B extinguisher: a carbon dioxide or powder extinguisher.
electrical
Dimensions (mm)
paraffin
including base plate:
3.10
0.80
Accessories:
50-120
0.323
Mains
*
258
Electrical consumption:
*
16.7
- igniter
*
- continuous
8.0
Fuse rating
level (NDIR CO
-sensor Q).
2
2
width 376
depth
296
height
428
- manual fuel pump
- transportation cap
230 V
-- AC / 50 Hz
320 W
13 W
250V, 5A
4
71
27-05-13 15:28

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières