Authorised Operators; Installation And Commissioning; Power Supply Connection; Power Failure - Vetus BC1216 Manuel D'utilisation Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

neglected when working with the Charger, the manu-
facturer or supplier will accept no liability for injury or
damage. In addition, such damage is no longer cov-
ered by the manufacturer's guarantee.
2.2 Use for correct purpose
The Charger is intended only for re-charging lead-acid accu-
mulators. Depending on the previously set charging program, it
can also be used for wet-cell batteries and sealed maintenance-
free traction batteries.
The unit can also be used for charging wet-cell batteries and
sealed maintenance-free traction batteries. Always observe the
instructions provided by the battery manufacturer.
The Charger is not suitable for accumulators or non-
rechargeable batteries of any other type!
The use of the unit for any other purpose is incorrect and con-
sequently prohibited. The operator of the Charger alone is
responsible for any damage occurring under such circum-
stances.
The use of the unit for its correct purpose includes compliance
with these operating instructions.
The Charger should be used only in technically perfect condi-
tion. The user must be constantly aware of potential danger and
safety procedures. Any faults, malfunctions or damage (espe-
cially those which may involve a risk to the safety of the opera-
tor of the Charger) must be corrected immediately. In case of
faults or malfunctions affecting its safety, the Charger must be
taken out of service immediately and reported to the supervisor
in charge or other responsible person or department.

2.3 Authorised operators

No person is authorised to operate the unit unless he has read
and understood the operating instructions.
Adjustments (e.g. voltage adjustment) or repairs (e.g. replace-
ment of the DC fuse) should be carried out only by a qualified
electrician.
2.4 Industrial use
If the Charger TEBECHOP Traction is in use for industrial pur-
poses, the following also applies:
The operator must have undergone special instruction or train-
ing to familiarise himself with the charging and handling of lead-
acid accumulators. Such tasks should be performed only by
authorised personnel.
For safety reasons, it is prohibited to make changes or modifi-
cations to the unit. Always observe the protective earthing.
Battery charger type BC1216, BC1225, BC1235, BC2416, BC2425, BC2450, BC2465
3
Design
The unit comprises a controllable high-frequency power unit,
microprocessor-controlled charging electronics and an operat-
ing and indicating panel with buttons and 4 LEDs.
The individual components are accomodated in a sturdy hous-
ing of steel sheeting. Cables are installed for connection to the
battery and power supply.
Note!
Always observe the power-supply data given on the
machine plate! The machine plate is located at the rear
of the unit.
4

Installation and commissioning

4.1 Installation
The unit should be used only in enclosed rooms. The place of
erection resp. the mounting room should be selected to ensure
that the ventilation openings are not covered and that the cur-
rent of cooling air is not obstructed. The unit must not be
installed or mounted close to radiators or other sources of heat.
It should also be ensured that no corrosive gases, e.g. acid
fumes, conductive dust etc. can penetrate the interior of the
unit. The protective system of the charger is IP 20.
4.2 Power-supply connection
The power-supply voltage and frequency must comply with the
data on the machine plate.
The unit must be protected against excessive contact voltage in
accordance with the regulations of the local electricity supplier.
The power supply fuse should be selected in line with the
following table:
Rated current
0 - 6 A
6 - 10 A
10 - 16 A
Either gL fuses or automatic circuit breakers with B- or C- char-
acteristics are suitable for use.

4.2.1 Power failure

The unit starts a new charging process after every disruption in
the power supply lasting longer than 20 ms.
ENGLISH
Mains fuse
6 A gL
10 A gL
16 A gL
9
9.0112

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bc1225Bc1235Bc2416Bc2425Bc2450Bc2465

Table des Matières