Function selector
F
1 ON - Closing only – with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF - Open-close – with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON - Only opening – with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF - Partial opening – with command device connected on contact 2-3P (2 ON – deactivated).
3 ON - Optical reader deactivated; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE:
make selections when motor is stopped and in the closed position.
Connecting two joined motors with a single command
1) Coordinate the direction of travel of geared motors "A" and "B", by modifying the rotation of motor "B".
2) Carry out the electrical connections on the geared-motor "A" command card as per paragraph 6.3 electrical connections.
3) On both cards, carry out the same settings and activate the same functions (Dip Switches)
4) Carry out the connections between the two command cards as per the fi gure.
Note: the (2-3P) partial opening button needs to be connected to the command card's terminal board of the motor in question (motor A
for opening left-wards, and B for opening right-wards).
5) On the geared motor A's command card, insert the AF radio card.
Activate the radio command, using the CH2 channel.
After memorising the code, connect contacts B1 and B2 on contacts 2 and 7.
On both cards, select the type of command (see Dip-Switches 2 and 3).