Front View; Side View; Ec Declaration Of Conformity - tau SS340 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6 Timing chart of events
Relay Output /  Test Input
Dip Switch #3
NON-
POWER OFF
DETECTION
Relay Output Mode
4
4
NO
NO
3
3
COM
COM
NO
5
5
NC
NC
4
4
NO
NO
3
3
NC
COM
COM
5
5
NC
NC
Test Input
Dip Switch #1
Test Input
Supplying DC12 to 24V,
B
make current flow from
7th terminal to 6th.
Break the current
T : 8 to 18 [mSec]
A
7 LED information
7-1 Normal state
State
Red LED
Non-Detect
Detect
7-2 Error state
Red LED
Green LED
N
Error category
1
Environmental error
3 over
Other Error
7-3 Teaching state
See Section 8
8 Teaching
Conduct the following steps with the Filter Cover off.
Check the wiring connection and supply power.
1
2
 Execute " TEACHING"
" TEACHING" is necessary to make the sensor work properly, that is to learn the distance from the sensor to
the floor.
STEP 1.
Press the " Push SW" switch
for more than 2 seconds.
STEP 2.
LED blinks slowly for 10 sec' s in a non-detection
state. Ensure that there are no people or objects
(ladder etc) in the detection area during this time.
Red LED
Green LED
3
Check the adjustments , range and other setting.
9 Detection Area

9.1 FRONT VIEW

1000
2000
2600
1000
800
600
400
200
10 Detection Range Check without Filter Cover
Check the detection range without the Filter Cover attached.
Put a test object in the detection area to check the detection patterns and other Dip Switch
settings. Tests according to local standards should be carried out.
After this check, Turn power off.
EN16005
Check that the detection area conforms to EN16005
When the test is completed, go to Section 11 to install the Filter Cover and Side Cover.
If an error occurs, re-check the settings referring to Section 3.
11 Replacing the Filter Cover and Side Cover
1
Installing the Filter Cover:
1)
First fit the upper side of the Filter Cover into the full
length of the Aluminum Case.
2)
Slightly bend the Filter Cover at one end to latch
it onto the bottom lip of the Aluminum Case.
3)
Slide your hand along the bottom lip to lock the Filter Cover
onto the Aluminum Case all along the length of the Aluminum
Case.
NON-
DETECTION
DETECTION
4
4
4
NO
NO
NO
3
3
3
COM
COM
COM
5
5
5
NC
NC
NC
4
4
4
NO
NO
NO
3
3
3
COM
COM
COM
5
5
5
NC
NC
NC
TEST RESPONSE
T
NON-TEST
TEST
Sensor
Sensor
7
7
6
6
Sensor
Sensor
7
7
6
6
Green LED
OFF
ON
PCB unit
ON
OFF
Cause
Solution
Execute the " TEACH" from
Environmental noise or the reflection
Section 8 whilst laying a sheet of
level from the floor is too low.
white paper on the floor.
Internal component failure
Change the units.
STEP 3.
After STEP2, LED blinks faster and starts " TEACHING". If during
this time, a person or object is in the detection area, try again from
STEP 1.
Red LED
Green LED
STEP 4.
After STEP3, the green LED blinks once and then this process is
completed.
Red LED
Green LED

9.2 SIDE VIEW

1000
25
2000
5
2600
0
1200
1000
800
600
400
!
Be careful not to obstruct
the optical components
with wires.
2
Attaching the Joint
1)
Snap the Joint into the Aluminum Case.
2)
Slide the Joint so that it fits snugly into the Filter
Cover. Make sure there are no gaps left.
3)
Attach remaining Filter Covers as illustrated
4
NO
3
COM
5
NC
4
NO
3
COM
5
NC
DETECTION as
1
response to TEST
T
3
NON-TEST
Cut out the Side Cover wiring point and insert the
Wire Sheath into it.
Sensor
7
6
Sensor
7
6
Green LED
12 Final Detection Range Check
After the Filter Cover is fitted, confirm that the detection range is as expected
and conforms with local regulations.
Check that the detection area conforms to EN16005
EN16005
" N"
Red LED
times
13 Technical Data
MODEL
TECHNOLOGY
POWER SUPPLY
CURRENT
CONSUMPTION
RELAY OUTPUT
TEST INPUT
MOUNTING HEIGHT
DETECTION RANGE
14
Dimensions
SS340
S1
SS
340
M1
Unit: [mm]
SS
340
L1

15. EC DECLARATION OF CONFORMITY

Description of Product:
SS340 Safety Sensor for Swing Doors.
Complete stationary detection with PSD distance measurement.
Directives Fulfilled:
DIRECTIVE 2006/42/CE
DIN 18650-1:2010
EN12978:2003 +A1:2009
EN62061:2005
EN ISO 13849-1:2008/AC:2009 Safety of machinery - Safety-related parts of control systems.
EN 16005:2012
Esame CE di tipo N. 44 205 13738001
Above EC Type Directives Certified by:
TUV NORD CERT GmbH
Langemarckstr.20 45141 Essen Germania
N. identificazione: 0044
Compiler of Technical File (EC Community)
David Morgan / Hotron Ireland Ltd
0
200
26 Dublin Street, Carlow, Ireland
Tel: +353 5991 40345
<Disclaimer> The manufacturer cannot be held responsible for the below.
1. Misinterpretation of the installation instructions, miss connection, negligence, sensor modification and inappropriate
installation.
2. Damage caused by inappropriate transportation.
3. Accidents or damages caused by fire, pollution, abnormal voltage, earthquake, thunderstorm, wind, floods and other
acts of providence.
4. Losses of business profits, business interruptions, business information losses and other financial losses caused by
using the sensor or malfunction of the sensor.
5. Amount of compensation beyond selling price in all cases.
CAUTION
2
Safety Sensor for Swing Doors    SS340
COMPLETE STATIONARY DETECTION with PSD DISTANCE MEASUREMENT
BEAM ANGLE
AC/DC 12〜24[V] ± 10%
ADJUSTMENT
RESPONSE SPEED
95 [mA] @ DC12[V]
55 [mA] @ DC24[V]
1.7 [VA] @ AC12 [V]
2.3 [VA] @ AC24[V]
DIP SW FUNCTIONS
DC 50V 0.1 [A]
NON VOLTAGE 1C
6 [mA] Max. at 24 [VDC]
OPERATING
2.6 [m] Max
TEMPERATURE
0 - 2.55 [m] Max
WEIGHT
360
692
1023
Machinery Directive
Powered pedestrian doors Part 1: Product requirements. Chapter 5.7.4
Industrial, commercial and garage doors and gates - safety devices for power operated doors
and gates - Requirements and test methods.
Functional safety of electrical/electronic/programmable electronic safety-related systems.
Power operated pedestrian doorsets - Safety in use - requirements and test methods. Chapter 4.6.8
Harmonized Standards Used:
EN ISO 13849-1:2008/AC:2009
Location of Declaration (Manufacture)
Honda Electron Co. Ltd
1-23-19 Asahi-Cho,Machida-City,
Fax: +353 5991 40543
Tokyo, Giappone
TAU SRL
Via E. Fermi, 43
36066 SANDRIGO (VI) ITALY
T +39 0444 750190 - F +39 0444 750376
www.tauitalia.com - info@tauitalia.com
3
4
Attach the Side Cover with
Screws provided.
Screw
5 , 10 , 15 , 20 , 25 [degrees]
LESS THAN 100 [mSec]
TEST INPUT : 1 [BIT]
OPTICAL INTERFERENCE : 1 [BIT]
RELAY OUTPUT MODE :1 [BIT]
MASKING DETECTING SPOTS:2[BIT]
DETECTION RANGE:3[BIT]
-20 〜 +60 [゜ C]
SS340
S1: 350[g] APPROX.
SS
340
M1: 540[g] APPROX.
SS
340
L1: 760[g] APPROX.
47.5
Unit: [mm]
48
48
Other Technical Standards Used:
DIN 18650-1:2005
EN16005:2012
Date
Declaration made by
Teruya Morimoto
30
September
Director
Quality Assurance
2015
rev.02 del 14-02-2017

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ss340s1Ss340m1Ss340l1

Table des Matières