Intended purpose: CAMOped is a treatment device and is used to move the knee or the hip gently at an
early stage of treatment.

Safety Advice

The patient may only make adjustments in
consultation with his/her treating doctor.
Should you experience excessive pain,
swelling, numbness, sensitivity changes,
unusual reactions or an uncomfortable
sensation during use, please contact your
doctor or orthopaedic technician immediately.
This treatment device was developed for
the indications stated and may be damaged
through unusual and non-intended use.
Please consult your treating doctor before
using it in conjunction with another medical
device.
Assembling and dismantling the footrests
Assembling the footrests
1. Insert the right footrest into the right slider
(marked in green). The black bolt must be
placed between the orange adjustment caps.
(a)
2. Insert the left footrest into the left slider
(marked in red). The black bolt must be
placed between the orange adjustment caps.
(b)
3. Please note that the black knob must be open
if you want to be able to move the footrest.
(f)
4. Press the footrests down firmly with both
hands until you hear a 'click'.
Marking on the device
The right footrest and slider are marked in green.
The left footrest and slider are marked in red.
10
The product must be cleaned and disinfected
and its functions must be tested after every
use.
The treatment device must undergo
maintenance (disassembly, cleaning and
functional tests) at least once per year.
Only replacement parts approved by OPED
GmbH may be used.
Note: Not made of natural rubber latex.
LATEX
In the event of malfunctions, repair work must
be carried out by a technician trained and
certified by OPED GmbH.
Dismantling the footrests
1. Press down the small round button on the
slider and remove the footrest. (c)
2. First place the CAMOped and then the boxes
with the footrests into the cardboard box. (e)
3. When putting them back in the packaging,
please ensure that both sliders are placed
in the middle. Otherwise, the inserts for the
frames won't fit perfectly.

Preparation

Angle restriction
Use the angle restriction to set the permitted
range that your leg can bend or stretch.
Your treating doctor will have told you how
far you are allowed to bend or stretch. If
you are unsure, please consult your doctor/
physiotherapist.
How to Use – Five Steps to Success
1. Position product
(Fig 1)
• Place the CAMOped with extended supports
between your legs.
• There should be a gap of approx. 10cm (one
hand's width) between the device and your
buttocks.
Tip: An instruction video for using on bed/couch/
floor can be found at www.camoped.com.
2. Insert legs
(Fig 2)
• Place your legs into the frames. Be careful
when inserting the injured leg!
• Both legs should be slightly bent here and the
sliders should be at the same height.
• The entire sole of the foot should have
contact with the foot plate.
3. Lower leg length adjustment
(Fig 3)
• Adjust the frames individually by sliding
them.
Always set the left and right sliders the same
on both sides (d)
The numbers 0-12 roughly correspond to
angles of 0°-120°
4. Close the belt straps
(Fig 4)
• Close all of the belt straps.
5. Position the sliders
(Fig 5)
Check whether the angle restrictions have been
correctly set and snapped closed. (d)
• Press down the long, curved button and keep
it held down to unlock the sliders.
• Extend one leg to the maximum extension
permitted and bend the other leg to the
maximum flexion angle allowed.
• Release the button again and the sliders will
snap into the desired position.
6. Start movement exercise
(Fig 6)
• Start slowly and concentrate on the
movement exercises.