Gree GWH09QB-K3DNA6C/I Manuel D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation of indoor unit
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
Step four: outlet pipe
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
right
1. Aim the pipe joint at the corresponding
bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Indoor
5-10
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
left
rear left
27
outdoor
cut off
the hole
pipe joint
union nut
Φ55/
Φ70
right
pipe

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gwh12qb-k3dna6c/iGwh18qd-k3dna6c/iGwh24qe-k3dna6g/i

Table des Matières