Air ow Selection and Adjustment

Air ow direction adjustment
The air ow path may be adjusted to distribute air independently from the
left or right side of the discharge opening. Each of the banks of louvers
can be directed left, right, up or down in order to achieve the most optimum
air ow positioning.
To adjust air ow direction grab the lever in the center of the louver bank and
move it in the direction that you would like the air to be directed. Please
note that it is normal that air ow may be stronger out of one side of the
louvers than the other.

Installation Instructions

WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner's
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
READ THIS FIRST! Electrical Requirements
Figure 12
LEFT AIRFLOW
LEVER
IMPORTANT: Before you begin the actual installation of the air conditioner,
be sure your electrical requirements are as described below. Consult an
electrical professional as necessary to insure home wiring is per local
electrical codes.
CIRCUIT PROTECTION – An overloaded circuit will invariably cause
malfunction or failure of an air conditioner, therefore, it is necessary that the
electrical protection is adequate. Due to momentary high current demand
when your air conditioner is started, use a "TIME DELAY" fuse or a HACR
type circuit breaker. Consult your dealer or power company if in doubt.
Your air conditioner must be connected to a power supply with the same
A.C. voltage and hertz as marked on the unit nameplate. Only alternating
current (A.C.), no direct current (D.C.), can be used.
The power cord has a plug with a grounding prong of approved type and a
matching plug receptacle with ground is required. Refer to page 6 for the
correct type of plug receptacle for your model.
RIGHT AIRFLOW
LEVER
FRR083
21