Plumbing Connections - Illinois Tool Works Stero SU-L Mode D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
The plumber connecting this machine is responsible for making certain that water lines are THOROUGHLY
FLUSHED OUT BEFORE connecting to the dishwasher. This "flush-out" is necessary to remove all foreign mat-
ter, such as chips (resulting from cutting or threading of pipes) pipe joint compound from the lines; or, if
soldered fittings are used, bits of solder or cuttings from the tubing. Debris, if not removed, may lodge in the
dishwasher's plumbing components and render them inoperative. Manual valves or solenoid valves fouled by
foreign matter and any expenses resulting from this fouling are NOT the responsibility of the manufacturer
and associated repair costs are not covered under warranty.
Water supply requirements are as follows:
Model
Description
SU-L
120°F Minimum
SU-H
110°F Minimum
SG
120°F Minimum
Required flowing water pressure to the dishmachine is 15-65 PSIG. If pressures higher than 65 PSIG are present,
a pressure regulating valve must be installed in the water line to the dishmachine (by others). If flowing pres-
sure is less than 15 psi, improper machine operation may result. The dishmachines are equipped with a pumped
rinse system; therefore, a water pressure gauge is not required and is not supplied with the machine.
The water pressure regulator must have a relief bypass. Failure to use the proper type of pressure
regulator may result in damage to the unit.
A manual shutoff valve (not supplied) should be installed upstream of the fill hose to accommodate servicing
the machine.
It is recommended that a line strainer (not supplied) be installed in the supply line between the manual shutoff
valve (not supplied) and the connection point on the machine. Make plumbing connections with
copper piping OD (
" recommended), with a
3
4
diagram,s, pages 12-14.

PLUMBING CONNECTIONS

Plumbing connections must comply with applicable sanitary, safety, and plumbing
codes.
Drain
A drain hose,
" inside diameter and 6' long, is provided. This should be securely plumbed into a drain. Use
5
8
care not to kink hose. See installation diagrams, pages 12-14. Drain must have a minimum flow capacity of
5 gallons per minute.
STERO UNDERCOUNTER DISHWASHER & GLASSWASHER
(continued)
" male garden hose fitting (not supplied). See installation
3
4
|
7
" minimum
1
2

Publicité

Chapitres

Table des Matières
loading

Table des Matières