14) MAINTENANCE

In order to get the best life out of your Walter machine always keep it in good working order.
A number of items must always be checked on Walter machines.
Always before starting any job make sure the machine is in good working order and that there are no
damaged or loose parts. Any loose parts must be tightened.
Before proceeding with any maintenance work be certain that the power supply is disconnected.
Description
Visual check of machine for damage
Operation of machine
Check brush wear
Check magnetic base
Check alignment of the machine
Check grease
Check armature
Visually check the machine for damage.
The machine must be checked before operation for any signs of damage that will affect the operation of the
machine. Particular notice must be taken to the mains cable, if the machine appears to be damaged it should
not be used, failure to do so may cause injury or death.
Check operation of the machine.
The machines operation must be checked to ensure that all components are working correctly.
Machine Brushes
Should be checked to make sure there is no abnormal wear present (this should be checked at least once a
week if used frequently). If the brush has worn more than 2/3 of the original length, the brushes should be
changed. Failure to do so may cause damage to the machine.
Magnetic base
Before every operation the magnetic base should be checked to make sure that there is no damage present.
An uneven magnet base will cause the magnet not to hold as efficiently and may cause injury to the
Original Instructions
- Damaged / defective wiring
- Motor seriously dirty
- Damaged or defective wiring
- Wrong value fuse
- Defective magnet switch
- Defective control unit
- Damaged or defective wiring
- Wrong value fuse
- Motor running roughly
- Defective armature and / or field
- Carbon brushes worn out
- Defective control unit
- Loose or defective gear-rack
- Defective rotation system
Every operation
1 week
X
X
X
13
1 Month
X
X
X
X