Troubleshooting - Walter Surface Technologies ICECUT MINI 39-D 050 Instructions D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ICECUT MINI Low-Profile
Cutter not attached tightly to arbor.
Insufficient use of cutting oil or unsuitable type of oil.
Incorrect speed
5) Excessive
See cause and remedy above
cutter wear
Incorrectly re-sharpened cutter.
Insufficient or spasmodic cutting pressure.

13) TROUBLESHOOTING

Magnet and motor do not function
Magnet does function, the motor does
not
Hole cutters break quickly, holes are
bigger than the hole cutter
Motor running roughly and/or seizing up
Motor making a rattling sound
Motor humming, big sparks and motor
has no force
Motor does not start or fails.
Guiding takes a great deal of effort
Insufficient magnetic force
Original Instructions
Retighten.
Inject oil of light viscosity into the coolant-inducing ring and check
that oil is being metered into cutter when pilot is depressed. If
not, check pilot groove and arbor internally for dirt or apply oil
externally. (Even a small amount of oil is very effective).
Ensure correct gear is used for the cutter.
Refer to instructions and a new cutter for proper tooth geometry.
Use sufficient steady pressure to slow the drill down. This will
result in optimum cutting speed and chip load.
- Damaged or defective wiring
- Defective fuse
- Defective control unit
- Defective power supply
- Damaged or defective wiring
- Carbon brushes are stuck or worn out
- Defective on / off switch
- Defective control unit
- Defective armature and/or field
- Defective protective reed switch
- Play in the guide
- Bent spindle
- Shaft extending from the motor is bent
- Pilot bent
- Bent spindle
- Shaft extending from the motor is bent
- Triangular guide not mounted straight
- Dirt between spindle and triangular guide
- Gear ring (bottom of the armature) worn out
- Gear(s) worn out
- No grease in gear box
- Armature damaged
- Field burned
- Carbon brushes worn out
- Damaged or defective wiring
- Damage to armature or field coil
- Damaged or defective brushes
- Guide is set too tight
- Guide is dry
- Guide/gear- rack/rotation system is dirty or damaged
- Bottom of magnet not clean and dry
- Bottom of magnet not flat
- Work piece is not bare metal
- Work piece is not flat
- Work piece is too thin less than 3.5mm
- Defective control unit
- Defective magnet
12