ASKAYNAK Plasma 105 ULTRA Manuel D'utilisation page 52

Le poste de coupage plasma
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance and Troubleshooting - 4
PROBLEM
While cutting, cutting
arc do not restart
after cut off.
Torch cuts but cutting
quality is low.
50
POSSIBLE REASON
Machine has entered
into thermal protection.
Air pressure is low.
Torch consumables
are faulty.
Cutting current is low.
Torch speed is too high.
Air flow is not sufficient.
Torch get oiled or
consumables reached
to their end of life.
SOLUTION
Wait machine to exit from
thermal protection.
Adjust air pressure.
Change torch consumables.
Increase cutting current.
Decrease torch speed.
Increase air current.
Clean the torch or replace
consumables with new ones.

Publicité

Table des Matières
loading

Table des Matières