EN
1. GENERAL INSTRUCTIONS
Carefully read and follow the instructions contained in this booklet.
After installing the unit, inform the user about its operation and give him this manual, which
is an integral and essential part of the product and must be kept for future reference.
Installation and maintenance must be carried out by professionally qualified personnel, in
compliance with the current regulations and according to the manufacturer's instructions.
Do not carry out any operation on sealed adjustment parts.
Incorrect installation or inadequate maintenance can result in damage or injury. The Man-
ufacturer declines any liability for damage due to errors in installation and use, or failure to
follow the instructions.
Before carrying out any cleaning or maintenance operation, turn off the gas by means of
the special shutoff devices.
In case of a fault and/or poor operation, deactivate the unit and do not try to repair it or
directly intervene. Contact professionally qualified personnel. Any repair/replacement of
the products must only be carried out by qualified personnel using original replacement
parts. Failure to comply with the above could affect the safety of the unit.
This unit must only be used for its intended purpose. Any other use is deemed improper
and therefore hazardous.
The packing materials are potentially hazardous and must not be left within the reach of
children.
The unit must not be used by people (including children) with limited physical, sensory or
mental abilities or without experience and knowledge of it, unless instructed or supervised
in its use by someone responsible for their safety.
The unit and its accessories must be appropriately disposed of, in compliance with the cur-
rent regulations.
The images given in this manual are a simplified representation of the product. In this rep-
resentation there may be slight and insignificant differences with respect to the product
supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
SKY C B is a high efficiency, instantaneous domestic hot water heater using natural gas
or propane gas, equipped with an open-flue burner with electronic ignition, battery pow-
ered, intended for indoor installation.
2.2 Control panel
Panel
3
5
1
fig. 1 - Control panel
Panel legend fig. 1
1
DHW temperature display
2
Battery level signalling
3
Off/burner power adjustment
4
Temperature adjustment
5
Flame symbol
Indication during operation
Table. 1 - Display symbols
Symbol flashing: the burner is lit.
If the burner is off, this symbol is not displayed.
Temperature of water at the water heater outlet.
Symbol steady. The battery is nearly flat. Replacement is recommended.
Symbol flashing. The battery is flat and needs replacing.
During a DHW demand (generated by drawing hot water), the display shows the actual
DHW outlet temperature.
8
EN

2.3 Lighting and shutdown

Preliminary operations and checks
1.
2.
3.
4.
Lighting
Turn the knob to the required water heating level.
The unit will immediately be ready to work whenever hot water is drawn.
Turning off
The burner goes off automatically when the demand for hot water ceases.
No particular operation is required in order to do another lighting phase.
To shut down unit, turn the knob to
In case of a prolonged shutdown, close the gas cock ahead of the unit.
B
2
4
2.4 Adjustments
Manual setting of burner power
Use the power adjustment knob (ref. 3 - fig. 1) to select the water heater power, minimum
or maximum and intermediate positions depending on the required water heating level.
Turn the knob anticlockwise and the unit heats the water at maximum power. If the tem-
perature is too high, for example in the summer, or when a reduced flow of not very hot
water is necessary, turn the knob clockwise. This reduces the power (and gas consump-
tion). In the position
Setting the temperature
The water temperature can be easily set with the temperature selector: turn it to the right
to increase the temperature, or to the left to decrease it.
Faults
After making the above adjustments, the water heater will be ready to work in completely
automatic mode. When a hot water tap is turned on, an intermittent discharge is gener-
ated on the ignition electrode, which causes lighting of the burner.
All electronic models have an ionisation electrode fitted in the burner to control the cor-
rect presence of flame. In case of a fault or no gas feed with consequent burner shut-
down, the hot water tap must be turned off.
It is therefore necessary to eliminate the cause of no gas reaching the water heater, e.g.
inadvertent closing of the gas cock, gas cylinder empty, etc.
Water heater shutdown is deactivated by turning the hot water tap off and on.
Repeat the operation if there is still no hot water after eliminating the cause and turning
on the hot water tap. If the problem persists, contact the After-Sales Service.
cod. 3541C702 - Rev. 01 - 06/2014
Make sure the hot water taps are closed.
Open the water heater gas supply cock, located on its gas connection.
Make sure the 1.5 V batteries are properly fitted, with the correct polarity (+ and -).
For their replacement see *** 'Replacing batteries' on page 11 ***.
Also make sure the batteries have enough charge for water heater operation.
fig. 2 - Lighting
.
fig. 3 - Unit deactivated
To avoid damage caused by freezing during long shutdowns in winter, it is ad-
visable to drain all water from the water heater.
the unit is deactivated.