KWP
SPN
FMI
571
5
584
3
590
4
572
5
585
3
591
4
573
5
543
11
544
11
956
3
960
3
957
4
961
4
958
5
959
12
426
3
427
4
424
5
425
12
545
5
547
12
305
9
452
3
457
3
453
4
458
4
D 23.18 84
Code
Error Identification
1-6-1
Injector 4 (in firing order); interruption of
electric connection
1-6-2
Injector 5 (in firing order); short circuit
1-6-2
High side to low side short circuit in the
injector 5 (in firing order)
1-6-2
Injector 5 (in firing order); interruption of
electric connection
1-6-3
Injector 6 (in firing order); short circuit
1-6-3
High side to low side short circuit in the
injector 6 (in firing order)
1-6-3
Injector 6 (in firing order); interruption of
electric connection
2-6-3
Cold start aid relay; open load, relay
error.
2-6-3
Cold start aid relay; open load, relay
error.
5-1-2
Starter relay; short circuit
5-1-2
Starter relay; short circuit
5-1-2
Starter relay; short circuit
5-1-2
Starter relay; short circuit
5-1-2
Starter relay; no load error
5-1-2
Starter relay; powerstage over tempera-
ture
1-4-2
Engine running lamp; short circuit to bat-
tery
1-4-2
Engine running lamp; short circuit to
ground
1-4-2
Engine running lamp; open load
1-4-2
Engine running lamp; powerstage over
temperature
2-6-3
Cold start aid relay open load
2-6-3
Cold start aid relay; over temperature
error
1-1-8
Timeout Error of CAN-Receive-Frame
TSC1TE; Setpoint
2-2-8
Fan control; short circuit to battery
2-2-8
Fan control; short circuit to battery
2-2-8
Fan control; short circuit to ground
2-2-8
Fan control; short circuit to ground
Short Text Detail
Injector 4 (in firing order); interruption of electric
connection
Injector 5 (in firing order); short circuit
High side to low side short circuit in the injector
5 (in firing order)
Injector 5 (in firing order); interruption of electric
connection
Injector 6 (in firing order); short circuit
High side to low side short circuit in the injector
6 (in firing order)
Injector 6 (in firing order); interruption of electric
connection
Cold start aid relay error.
Cold start aid relay open load
Starter relay high side; short circuit to battery
Starter relay low side; short circuit to battery
Starter relay high side; short circuit to ground
Starter relay low side; short circuit to ground
Starter relay; no load error
Starter relay; powerstage over temperature
Engine running lamp; short circuit to battery
Engine running lamp; short circuit to ground
Engine running lamp; open load
Engine running lamp; powerstage over temper-
ature
Cold start aid relay open load
Cold start aid relay; over temperature error
Timeout Error of CAN-Receive-Frame
TSC1TE; Setpoint
Digital fan control; short circuit to battery
Fan actuator (PWM output); short circuit to bat-
tery
Digital fan control; short circuit to ground
Fan actuator (PWM output); short circuit to
ground