FURTHER SPECIFICATIONS TO BE CONSIDERED
The stove functions with the combustion chamber in depression; it is fundamental that the exhaust is hermetically sealed.
It is recommended to use rigid stainless steel pipes, with sealing gaskets, with diameter of 80 mm.
The pipes must have a double wall or be suitably insulated with rock wool. The maximum temperature of the pipe must not exceed 70 °C.
IT IS MANDATORY TO REALISE A FIRST VERTICAL TRACT OF AT LEAST 1.5 METRES IN ORDER TO GUARANTEE CORRECT FLUE GAS
EXPULSION.
Every direction change must be carried out with T-shaped fitting and inspection cap.
The pipes must guarantee sealing against flue gas via the gaskets resistant to 250 °C.
Fix the pipes to the wall with the relevant metal collars in order to prevent any vibrations.
ATTENTION: IT IS PROHIBITED TO INSTALL DRAUGHT REGULATION VALVES (BUTTERFLY VALVES).
O 100 mm
ISPECTION
ISPECTION
O 80 mm
ISPECTION
MAXIMUM 500 mm
If a "traditional" flue is used for discharging the flue gas, make sure that is in good working order and complies with the standards currently in force. If the
flue should be too big (internal diameter greater than 14 cm), duct the flue using an appropriately insulated stainless steel pipe (using rock wool
or vermiculite) and dimensioned on the basis of the route. The connection to the flue must be appropriately sealed.
When assembling the flue, directions must not exceed 4 changes, including the initial T-shaped fitting. The maximum length of the horizontal
tract allowed is of 2 metres. Before carrying out horizontal movements, carry out a vertical tract of at least 1.5 metres.

ELECTRICAL CONNECTION

The electric connection must only be performed by qualified staff, with respect to all general and local Safety Standards in force.
Check that the power supply voltage and frequency correspond to 220V – 50 Hz.
Appliance safety is obtained when it is correctly connected to an efficient earth plant.
In the electric connection to the mains power supply, envision a differential magnet circuit breaker switch at 6 A – Id 30 mA with relevant breaking load. The
electric connections, including the earth, must be made after the voltage has been removed from the electric plant.
When realising the system remember that the cables must be placed in an unmovable and away from parts subject to high temperatures. During the final
wiring of the circuit, only use components with a suitable electric protection rating.
KLOVER srl declines all responsibility for injury to persons, animals or damage to objects deriving from failure to connect the stove to earth and
failure to comply with IEC Standards.
The electronic control unit manages and controls all stove functions always assuring excellent functioning of the entire appliance.
The stove can be installed in the same room as another boiler as long has this has a sealed chamber.
THE STOVE MUST BE INSTALLED EXCLUSIVELY BY QUALIFIED STAFF. SCRUPULOUSLY COMPLY WITH THAT STATED IN THIS GUIDE.
THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR DAMAGE CAUSED BY INCORRECT ASSEMBLY.
DO NOT PASS ELECTRIC CABLES IN THE IMMEDIATE VICINITY OF THE FLUE GAS PIPE, UNLESS THEY ARE INSULATED WITH SUITABLE