Falltech DuraTech 6 Mini Single Manuel De L'utilisateur page 8

Dispositif auto-rétractable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.5 Swing Fall: A swing fall occurs when the worker moves laterally out from under the anchorage and creates an expanded work zone
condition, see Figure 7. If a fall event occurs, the worker would swing back toward the anchorage. The swinging action generates
considerable force, and if the worker strikes an obstruction or makes contact with the lower level or the ground, this force could cause
severe injury or death.
Overhead Anchorage and Swing Fall: For each foot the user moves laterally in any direction away from the anchorage, the work zone
expands and swing fall forces increase. This increased force requires additional MRFC distance. See Chart 1 below for instructions
on calculating additional fall clearance distance caused by expanded work zone swing fall conditions.
Chart 1 - Additional Fall Clearance Due To Swing Fall for Overhead Anchorage, Non-Leading Edge
Dorsal
D-Ring
1 foot increments along the X-Axis represent the
distance the user is working away from the SRD Anchorage
Example:
With leg-end snap hook connected to the Dorsal D-ring on FBH, User installs a 6' SRD unit 3' overhead (up the Y axis) and 3'
laterally (along the X axis). This intersection shows 1' of additional Fall Clearance needed caused by Swing Fall. This
additional 1' must be added to the MRFC for Overhead Use shown in Figure 6.
Key to Work Zone Areas:
CMSRD07 Rev A
Figure 7 - Swing Fall Hazards
6
0
0
5
0
0
4
0
0
3
0
0
2
0
0
1
0
0
0
0
1
0
1
X-Axis: Lateral Work Zone (ft)
Using Chart 1 to Find Additional Fall Clearance for Overhead Anchorage
To find the additional Fall Clearance needed to compensate for potential Swing Fall,
note the starting location on Chart 1 titled Dorsal D-Ring
= Allowable Use Area
A
Anchorage
6' Single-leg Self-Retracting Device
B
Walking/Working Surface
C
Swing Fall Impact After Fall Event
D
E
Next Lower Level or Obstruction
See Chart 1 for Additional Swing Fall Hazard Due To
Increased Fall Distance
0
1
1
0
1
1
0
1
2
1
1
2
1
2
2
1
2
3
2
3
4
2
3
4
1 foot increments up the Y-Axis represent the SRD
Anchorage height above or below the user's Dorsal D-Ring
= Cautionary Use Area
040220
2
2
2
3
2
3
3
4
3
4
4
5
5
6
5
6
= Not Allowed Use Area
8

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Duratech 6 mini twin