The through-the-wall installation is the least expensive and simplest installation. In a
through-the-wall installation you should be mindful of the snowdrift line, as well as dead
grass and leaves. We recommend a three foot (3') minimum vertical rise on the inside or the
outside of the dwelling.
When venting the stove through the ceiling, the pipe is connected the same as through the wall,
except the clean out tee is always on the inside of the house, and a 3" adapter is added before the
clean-out tee. You must use the proper ceiling support flanges and roof flashing supplied by the pipe
manufacturer -- follow the pipe manufacturer's directions and Illustration 1 in this manual. It is
important to note that if your vertical runs of pipe are more than fifteen feet (15'), the pellet vent pipe
should be increased to four inches (4") in diameter. Do not exceed four feet (4') of pipe on a
horizontal run, and do attempt to use the least number of elbows in the flue system. If an offset is
used it is better to install a 45-degree elbow whenever possible. NOTE: Installing elbows may inhibit
your draft by up to 15% per elbow.
If you are replacing a wood stove with a pellet unit the chimney or pipe should be thoroughly
cleaned before proceeding with the installation. If connecting this stove to a factory built chimney, it
may ONLY be a 6" flue, UL103 HT venting system (ULC S629 if Canada). Connection to any other
factory built chimney may result in a poorly operating or dangerous stove installation.
connecting to an existing masonry chimney, the cross-sectional area of the flue must be considered.
A chimney with a flue larger than 6" round (28.27 sq. in.) may require relining with an approved pellet
stove chimney lining system. Make sure the chimney meets the minimum standards listed in NFPA
211 (A chimney professional can confirm this upon inspection).
Outside air is mandatory for this unit to operate properly. This unit has been designed and tested
with this connection, because so many homes are airtight and there is not adequate combustion air
available inside the dwelling. The air intake pipe is located on the bottom side of the burn pot (from
the rear) and measures 1 ½" inside diameter (I.D.). The connection can be made with a metal 1
I.D. coupler and pipe (see "Important Information" section of manual), and should exit through the
wall. Be sure to secure the pipe to the unit with a clamp or aluminum tape. The outside end of the
pipe should be covered (screened) to prevent foreign matter from entering the system. Our Outside
Air Kit (Part Number PU-OAK) can be used. If the unit is located below ground level, you will need to
run the pipe up and then outside the dwelling. NOTE: If the total run of the connection exceeds 6', if
more than 2 elbows are used, or if a basement installation, use 3" metal pipe (and coupler) instead.
Note: If an older unit, measure the opening to determine what size pipe to use or couple to.
Secure the heater to the floor using the two holes in the pedestal. If the unit is on a combustible
surface, you will need to drill matching holes in the floor protection that you choose (see Floor Protection
section). Do not disturb the structural integrity of the home, be sure the unit is permanently electrically
grounded to the chassis of your home and remember that outside combustion air is mandatory. The wood
stove MUST be secured to the floor of the mobile home using lag bolts and the holes provided in the
bottom of the unit for this purpose. Use a #8 copper wire to ground stove to frame of mobile home.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL AND
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation.
Call 800-245-6489 and/or consult a professional installer if you have any questions.
IMPORTANT: Improper hook-up (too much pipe, too many elbows, etc.) will cause the unit not to operate.
Call Technical Support (800-245-6489) if you have questions about your hook-up or if your unit will not
operate.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.

Through the Ceiling

Existing Flue System

Outside Air (Outside Combustion Air Intake)

Mobile Home Installation

WARNING: DO NOT INSTALL IN SLEEPING ROOM
CEILING/ROOF MUST BE MAINTAINED.