Installation

Specifications

Electrical Service — All Models With Gas Heat
Single Oven
Double Stack
Triple Stack
International Ovens
(Single Stack)
General Information – 3240 Natural Gas Ovens
Model
Energy
Single Oven
Nat. Gas
Double Stack
Nat. Gas
Triple Stack
Nat. Gas
Single Oven
Nat. Gas
G20
Single Oven
Nat. Gas
G25
General Information – 3240 Propane Gas Ovens
Model
Energy
Single Oven
L.P. Gas
Double Stack
L.P. Gas
Triple Stack
L.P. Gas
Single Oven
L.P. Gas
G30
Single Oven
L.P. Gas
G31
GAS PRESSURE CONVERSION CHART
Inches of Water Column
3.5
4.5
7
10
10.5
11
14
14.5
10
Voltage (AC)
Phase
120
120
120
230/240
Power
Voltage
115,000 BTU
120 VAC
230,000 BTU
120 VAC
345,000 BTU
120 VAC
31 kW (HI)
230 VAC
144 MS/hr
3.88 m
/hr
3
26 kW (HI)
230 VAC
Power
Voltage
115,000 BTU
120 VAC
230,000 BTU
120 VAC
345,000 BTU
120 VAC
37 kW (HI)
230 VAC
2.315 kg/hr
31 kW (HI)
230 VAC
144 MS/hr
1.14 m
/hr
3
2.545 kg/hr
Millimeters of
KPa
m-Bar
Water Column
0.87
8.7
1.12
11.2
1.74
17.4
2.48
24.87
2.61
26.11
2.73
27.36
3.48
34.81
3.61
36.05
Hz
1
60
1
60
1
60
1
50
Current
Phase
6 Amps
1
12 Amps
1
18 Amps
1
3.15 Amps
1
3.15 Amps
1
Current
Phase
6 Amps
1
12 Amps
1
18 Amps
1
3.15 Amps
1
3.15 Amps
1
All ovens require separate service and dedicated
neutral.
Specifications
Body: Stainless Steel
DB Level: ≤ 71dba
88.9
114.3
177.8
NOTE: For proper operation, the gas valve requires
254
a nominal inlet pressure of 7 inches H2O column for
266.7
natural gas and 11 inches of H2O column for L.P. gas. A
minimum inlet pressure of 1.0 inch of H2O above the
279.4
manifold setting (NAT. manifold 3.5" H2O, L.P. manifold
355.6
10" H2O) must be maintained with no pressure drop
368.3
from the no load to full load condition. The maximum
inlet pressure must be maintained at or below ½ psig
(14.5 inches H2O column). Refer to the chart on the
left for pressure conversions.
Gas Supply
Hz
Pressure
60 Hz
8 – 14" W.C.
60 Hz
8 – 14" W.C.
60 Hz
8 – 14" W.C.
50 Hz
2.00 ‑ 3.48 kPa
50 Hz
2.00 ‑ 3.48 kPa
Gas Supply
Hz
Pressure
60 Hz
11.5 – 14" W.C.
60 Hz
11.5 – 14" W.C.
60 Hz
11.5 – 14" W.C.
50 Hz
2.85 – 3.48 kPa
50 Hz
2.85 – 3.48 kPa
Power: Gas and/or Electric
Operating Temperature
Range: 300°F ‑ 600°F
(149°C ‑ 316°C)
Part Number 11020000487 Rev A (2/16)
Section 2
Gas Pipe Size
(NPT)
3/4"
1"
1‑1/4"
3/4"
3/4"
Gas Pipe Size
(NPT)
3/4"
1"
1‑1/4"
3/4"
3/4"