Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EVERPURE
®
EF-1500 Cartridge - Part No. EV985850
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
• Finely polishes treated water to premium quality for drinking and
cooking.
• Reduces chlorine taste and odor.
• NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
• Reduces common earthy, moldy, fishy tastes and odors.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Influent Challenge
Max. Permissible Product
Substance
Concentration
Water Concentration
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulate,
Class I
at least 10,000
particles 0.5
particles/mL
to <1 µm
Standard 53—Health Effects
Cyst
Minimum 50,000/L
Lead 8.5
0.15 mg/L ± 10%
Lead 6.5
0.15 mg/L ± 10%
*Tested using flow rate = 2.2 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
• Capacity: 1500 gallons (5,600 liters)
• Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 2.2 gpm (8.3 lpm)
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
• Space required: 5"W x 15"H x 5"D (13 x 38 x 13 cm) including 2-1/2
inches of clear space under unit for cartridge change.
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush new cartridge at full flow for three minutes to purge air.
• Replace cartridges when capacity is reached, or when flow becomes
too slow, but at least annually.
4 • EVERPURE
EF-Series System
Reduction
Minimum
Requirements
Reduction
≥ 50%
≥ 85%
99.95%
99.99%
0.010 mg/L
98.1%
0.010 mg/L
99.3%

PERFORMANCE DATA SHEET

SPECIAL NOTICES
• Installation instructions, parts and service availability, and standard
warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer's instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction that may contain
filterable cysts.
• The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tests run under standard laboratory conditions. Actual performance
may vary.
• Spent adsorption media will not be regenerated and used.
• If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
EPA Est. 002623-IL-002
Average
The EF-1500 is Tested and Certified by NSF
Reduction
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
97.2%
Data Sheet.
C
US
99.9%
99.99%
98.8%
99.3%
EV314126 REV B DE17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Everpure ef-6000Everpure ef-3000Everpure ef-1500

Table des Matières