Flat Wall Installation - Chauvet Professional F4 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting

Flat Wall Installation

Mounting Points on a Flat Wall
At least 1 mounting point for every
junction (circled above) must be secured,
including outside edges and corners.
4 columns + 1
= 5 steel struts
12
Refer to the following diagram for flat wall installation.
Threaded Mounting Holes
M12 bolts must be used
The 4 rear and front mounting holes are intended for flush mount installation to a
flat surface against the video panels. 1 mounting point for every junction,
including outside edges and corners, must be used in order to maintain structural
integrity. The mounting points are not intended for hanging or suspending from a
truss or other overhead structure.
Chauvet recommends using a VERTICAL steel strut for each column of panels,
plus 1, as in the following diagram:
The illustrations above are examples only. Please refer to all applicable local
codes and regulations for the proper installation of the product.
Rear
Size M12 (4x)
for rear mounting
applications
Front
Mounting Holes
Size M10 (4x)
SAE 3/8 or M10 bolts are
compatible for front
mounting applications
F4 User Manual, Rev. 2

Publicité

Table des Matières
loading

Table des Matières