Fitting Instructions; Installation Recommendation - Eco-King Saga-S 200 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.5.5 Fitting instructions

!
The product must be filled with water before the power is switched on.
Any overflow pipe from the safety valve MUST be >
!
undamaged and frost-free sloping downwards to the drain/gully.
The product should be placed in a room with drain to avoid any material damage in case
!
of leakage. Liability for consequential damage will only apply if this is followed.
The product should be properly aligned vertically and horizontally, on a floor suitable for
!
the total weight of the product when in operation. See 2.4.
The product must have a clearance for servicing of minimum 40 cm in front of the junc-
!
tion box cover and sufficient space for servicing above the top.

3.5.6 Installation recommendation

Mains power cable (4) should be hidden under the channels in the bottom of the product.
-
If a non-return valve is fitted, a reduction valve and expansion vessel should be fitted to
-
prevent dripping from the T&P valve.
If the maximum water pressure exceeds 6 bar in a 24-hour period, a pressure reduction valve
-
and expansion vessel should be fitted.
For installation in a room without drain a watertight drip tray with overflow pipe > 18 mm.
internal diameter should be fitted under the product, in addition to an automatic stop valve
-
with sensor. This can prevent possible material damage.
!
WARNING
!
CAUTION
RECOMMENDATION
ø
18 mm inside, uninterruptable,
4
9

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Saga-s 300