5. USER GUIDE

5.1 Settings

5.1.1 Thermostat setting

The thermostat on the product is adjustable
from 45-75°C/113-167°F. The thermostat should
not be set lower than 65°C/149°F to prevent
bacteria growth.
!
Increasing the water temperature in the water
heater increases risk of scalding.
To adjust the temperature:
A) Disconnect the power supply.
B) Remove the junction box cover (4) by un-
screwing the fastening screw (5).
C) Adjust the temperature on the thermostat
(7) with a screwdriver.
Re-fit the junction box cover before connecting
the power supply.

5.1.2 Resetting the safety thermostat

The safety thermostat on the product cuts out
when there is a risk of overheating. This is re-
set by removing the cover and pressing the red
'RESET' button (6). If the thermostat cuts out re-
peatedly, contact the installer.
5.1.3 Anode (also see pt. 5.2)
B

5.2 Maintenance

Maintenance should be carried out by persons over 18 years of age, with suf-
!
ficient understanding
!
Annual inspection of T&P valve:
Open valve for 1 min. by lifting the lever (8) approx. 90 degrees to the open
-
position. CAUTION: Hot water will be released from the valve.
-
Visually check that the water is flowing freely to the drain.
-
YES = OK. Close the valve by setting the lever (8) back to the closed position.
NO = NOT OK. Disconnect power supply and shut off water supply. Con-
-
tact installer or a Certified Licenced Professional.
Annual inspection of anode (9), first time after 6 months in service: Turn off
power and water supply. Release water pressure by opening a hot water
-
faucet. Unscrew anode, lift and inspect. Replace if anode is depleted (see
illustration 'B' above). Illustration 'A' (above) shows a new anode.
WARNING
A

MAINTENANCE INSTRUCTIONS

!
WARNING
Constant voltage present in the junction box.
Before any electrical work is done, the power
supply must be disconnected and secured
against activation while the work is in progress.
1
6
2
1
THERM-O-DISC
2
7
3
4
8
9
13

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Saga-s 300

Table des Matières