OBJ_BUCH-0000000246-002.book Page 19 Thursday, March 9, 2017 9:06 AM
Repair and customer service.
Before mounting or replacing application tools or accessories, remove the bat-
WARNING
tery. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Exchangeable parts
If required, you can change the following
parts yourself:
Application tools
Service.
Have maintenance carried out
WARNING
only through qualified person-
nel. Incorrectly mounted leads and compo-
nents can cause serious injuries. Have the
required service carried out only through a
FEIN customer service agent.
The current spare parts list for this power
tool can be found in the Internet at
www.fein.com.
Cleaning.
Remove the battery prior to
WARNING
any maintenance and clean-
ing. This preventive safety measure rules out
the danger of injuries through accidental start-
ing of the power tool.
Warranty and liability.
The warranty for the product is valid in accordance with the legal regulations in the country
where it is marketed. In addition, FEIN also provides a guarantee in accordance with the FEIN
manufacturer's warranty declaration.
All accessories described or shown in this instruction manual will not be included with your-
power tool.
Environmental protection, disposal.
Packaging, worn out power tools and accessories should be sorted for environmental-friendly
recycling.
Dispose of batteries only when discharged.
For batteries that are not completely discharged, insulate the terminals with tape as a protective
measure against short-circuiting.
For further information, please contact your specialist shop.
When using in environments
WARNING
with conductive dust in the
air, such as when working metals, this dust
can settle in the interior of the power tool.
Therefore, regularly blow out the interior of
the power tool from outside via the ventilation
openings with dry, oil-free compressed air;
always wear eye protection when doing this.
Do not attempt to clean
CAUTION
clogged or dirty ventilation
openings of the power tool with pointed
metal objects; use nonmetal tools or objects
if necessary.
Do not use cleaning agents
CAUTION
and solvents that can cause
damage to plastic parts. These include: Gas-
oline, carbon-tetrachloride, chloric solvents,
ammonia and domestic cleaning agents that
contain ammonia.
en
19