Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

www.zephyronline.com
Monsoon I
AK9228AS
AK9234AS
AK9228AS290
AK9234AS290
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
MAR12.0201 © 2012 Zephyr Ventilation
READ AND SAVE THESE INSTRUCTIONS

Publicité

Table des Matières
loading

Sommaire des Matières pour Zephyr Essentials Monsoon I AK9228AS

  • Page 1 www.zephyronline.com Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 Model number: Serial Number: Date of Purchase: Sales Dealer: MAR12.0201 © 2012 Zephyr Ventilation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ................LIST OF MATERIALS ..............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifi cations ............... Electrical ................. Cabinet Preparation & Installation ....... Vertical Ducting Preparation ........Horizontal Ducting Preparation 12-14 ......FEATURES & CONTROLS Touch Controls 15-16 .............
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
  • Page 6 www.zephyronline.com MODELS: AK9228AS(290) AND AK9234AS(290) PARTS SUPPLIED 1 - Liner hood body 2 - Baffl e fi lters (3 for AK9234AS) 2 - Halogen light bulbs (pre-installed) 1 - Internal blower (pre-installed) 1 - 8” round adaptor w/damper 1 - 3 1/4” x 10” rectangular adaptor w/damper 2 - Horizontal ducting blower mount brackets 1 - Top rectangular cover plate 1 - Hardware package...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
  • Page 8 www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fi...
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options side wall cap w/ gravity damper...
  • Page 10 www.zephyronline.com 3/4 View (28”)14- ” (34“)17- ” (28”)9- ” (34“)12- ” elec. Top View (28”) 9- ” (34“)12- ” ” ” Back View...
  • Page 11 ELECTRICAL WARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the liner. If possible, power up and test all functions prior to installation. 1. Remove all packing materials and protective fi lm prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel.
  • Page 13 2. Remove grease tray by: 1) Pulling up on tray to 1. Remove baffl e fi lters by: 1) Pulling fi lter toward release from bottom panel. 2) Lifting tray out of front of liner. 2) Pivoting rear of fi lter down. liner body.
  • Page 14 www.zephyronline.com 2. Remove grease tray by: 1) Pulling up on tray to 1. Remove baffl e fi lters by: 1) Pulling fi lter toward release from bottom panel. 2) Lifting tray out of front of liner. 2) Pivoting rear of fi lter down. liner body.
  • Page 15 Rect. ducting Round ducting 8. Remove knock-outs A and B for rectangular 7. Using a fl at head screwdriver, remove 8” round ducting. Remove knock outs B and C for round or 3 1/4”x10” rect. knock-out plates at the back ducting.
  • Page 16 www.zephyronline.com 10. (Rectangular Ducting) From inside the liner, 10. (Round Ducting) From inside the liner, push push 3-1/4” x 10” rectangular adaptor through 8” round adaptor through the back knock-out the back knock-out and secure to interior back and secure to interior back wall of liner with (4) wall of liner with (8) M4 x 6mm screws.
  • Page 17 Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. 2.
  • Page 18 www.zephyronline.com Baffle Filter Clean Reminder A set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
  • Page 19 FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compli- ance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device.
  • Page 20: Surface Maintenance

    www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
  • Page 21: Replacing Light Bulbs

    REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise.
  • Page 22 www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR MONSOON I Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 23 Blower Fan Curve Model: AK92 (Monsoon I) AC Input: 120V, 60Hz Outlet Diameter: 8in 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Flow rate (CFM) Model: AK9228AS AK9234AS...
  • Page 24 www.zephyronline.com Blower Fan Curve Model: AK92-290 (Monsoon I) AC Input: 120V, 60Hz Outlet Diameter: 8in 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 Flow rate (CFM)
  • Page 25 DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 AK9228AS / AK9234AS Baffl e Filter, Large (each) 50210013 AK9234AS Baffl e Filter, Small (each) 50210017 RF Remote Control 14000005 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 26 STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain Limited Warranty service under warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you”...
  • Page 27 www.zephyronline.com Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 Numéro de modèle Numéro de série Date d’achat Détaillant MAR12.0201 © Zephyr Corporation LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 28 www.zephyronline.com...
  • Page 29 MISE EN GARDE DE SÉCURITÉ ......... LISTE DU MATÉRIEL ..............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ....Spécifi cations ............... Électricité ................ Préparation et installation des armoires ....
  • Page 30 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 31 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. CETTE HOTTE N’EST PAS CONÇUE POUR UNE UTILISATION AVEC UN GRIL EXTÉRIEUR ATTENTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
  • Page 32 www.zephyronline.com MODÈLES: AK9228AS(290) ET AK9234AS(290) PIÈCES FOURNIES 1 - Boîtier de hotte interne 2 - Filtres défl ecteurs (3 pour le AK9234AS) 2 - Ampoules halogènes (préinstallées) 1 - Ventilateur interne (préinstallé) 1 - Adaptateur circulaire de 8” avec registre 1 - Adaptateur rectangulaire de 3-1/4”...
  • Page 33 Longueur x Pièces de conduit Longueur x Pièces de conduit Total Total Nombre utilisé Nombre utilisé 3-1/ 4” x 10” 1 pi 6” 30 pi rect., droit embout mural circ./registre 6” circ., droit 1 pi 6” 30 pi chapeau de toiture circ.
  • Page 34: Conduit D'aération

    www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible – séparés par au moins une pièce standard – l’un de l’autre. La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 36”.
  • Page 35: Avertissement De Risque D'incendie

    AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
  • Page 36: Vue De Haut

    www.zephyronline.com Vue 3/4 (28”)14- ” (34“)17- ” (28”)9- ” (34“)12- ” Entrée dèfonçable Vue de haut (28”) 9- ” (34“)12- ” ” ” Vue arrière...
  • Page 37 ÉLECTRICITÉ AVERTISSEMENT Tous les travaux électriques doivent être réalisés par un électricien qualifi é ou par une personne possédant l’expérience technique et le savoir-faire nécessaire. Pour votre sécurité, enlevez le fusible ou ouvrez le disjoncteur de circuit avant de commencer l’installation. N’utilisez pas de cordon prolongateur ou de fi...
  • Page 38 www.zephyronline.com ATTENTION: Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. Dans la mesure du possible, allumez l’appareil et assurez-vous du bon fonctionnement de toutes les fonctions avant de procéder à l’installation. 1. Enlevez tout le matériel d’emballage et la pellicule de protection avant de procéder à...
  • Page 39 Enlevez les fi ltres défl ecteurs de la façon suivante : (1) Enlevez le collecteur de graisse de la façon suivante : Tirez le fi ltre vers l’avant du boîtier. (2) Faites pivoter (1) Poussez le collecteur vers le haut pour le libérer du l’arrière du fi...
  • Page 40 www.zephyronline.com Enlevez les fi ltres défl ecteurs de la façon suivante : (1) Enlevez le collecteur de graisse de la façon suivante : Tirez le fi ltre vers l’avant du boîtier. (2) Faites pivoter (1) Poussez le collecteur vers le haut pour le libérer du l’arrière du fi...
  • Page 41: Vous Devez Maintenant Fixer Le Boîtier

    Conduit rectangulaire Conduit circulaire À l’aide d’un tournevis plat, enlevez l’entrée Enlevez les entrées défonçables A et B pour installer défonçable circulaire de 8” ou l’entrée défonçable un conduit rectangulaire. Enlevez les entrées rectangulaire de 3 1/4”x10”, toutes deux situés à défonçables B et C pour installer un conduit circulaire.
  • Page 42: La Préparation Pour L'installation

    www.zephyronline.com (Conduit rectangulaire) À partir de l’intérieur du (Conduit circulaire) À partir de l’intérieur du boîtier, boîtier, installez l’adaptateur rectangulaire de 3-1/4” installez l’adaptateur circulaire de 8” dans l’entrée x 10” dans l’entrée défonçable arrière et fi xez-le à la défonçable arrière et fi...
  • Page 43 Ventilateur Marche/Arrêt Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumières Allumer/Veilleuse/Éteindre Choix de 6 vitesses Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1.
  • Page 44 www.zephyronline.com Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres. La fonction de rappel de nettoyage des filtres du microprocesseur indique automatiquement, à...
  • Page 45: Fonctions De La Commande À Distance

    Mise en garde de la Commission fédérale des communications: Dans le but d’assurer une conformité continue, toute modification apportée sans l’approbation expresse du parti responsable de la conformité pourrait annuler l’autorisation de l’utilisateur de faire fonctionner cet appareil. (Exemple – N’utilisez que des câbles d’interface armés lors du branchement à...
  • Page 46: Entretien Des Surfaces

    www.zephyronline.com ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. N’utilisez pas de produits à blanchir au chlore ou d’agents nettoyants «...
  • Page 47: Remplacement Des Ampoules

    REMPLACEMENT DES AMPOULES ATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées. Veuillez NE PAS les toucher avant de les avoir éteintes et laissées refroidir. Le contact avec les ampoules chaudes pourrait causer de sérieuses brûlures. Assurez-vous que l’alimentation électrique est coupée et que les ampoules ne sont pas chaudes. Enlevez les ampoules en les dévissant dans le sens contraire des aiguilles d’une montre.
  • Page 48 www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LA HOTTE MONSOON I Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’installation, l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 49: Protégé Thermiquement

    Courbe de rendement du ventilateur Modèle : AK92 (Monsoon I) Entrée en CA : 120V, 60Hz Diamètre du conduit de sortie : 8" 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Débit (pi3/min) Schéma de circuits Blanc...
  • Page 50 www.zephyronline.com Courbe de rendement du ventilateur Modele: AK92-290 (Monsoon I) Entree en CA: 120V, 60Hz Diametre du conduit de sortie: 8" 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 Debit (pi3/min) Schéma de circuits Blanc Modèle AK9228AS290...
  • Page 51 DESCRIPTION Nº DE PIÈCE Pièces de remplacement Ampoule MR16 (GU10) 35W Z0B-0023 Filtre défl ecteur pour AK9228AS/AK9234AS, grand (chaque) 50210013 Filtre défl ecteur pour AK9234AS, petit (chaque) 50210017 Commande à distance RF 14000005 Pour commander des pièces, visitez-nous en ligne au www.zephyronline.com ou communiquez avec nous par téléphone au 1-888-880-8368...
  • Page 52: Agrafez Votre Reçu Ici

    AGRAFEZ VOTRE REÇU ICI Une preuve de la date d’achat originale est nécessaire pour obtenir du service Garantie limitée lorsque le produit est sous garantie POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Corporation (désigné...

Ce manuel est également adapté pour:

Monsoon i ak9234asMonsoon i ak9228as290Monsoon i ak9234as290

Table des Matières