Technical Specifications; Description Of Components; Description Of Terminal-Boards; Programming The Logic - FAAC E012S Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19

3. TECHNICAL SPECIFICATIONS

230 (+6% -10%) 50 Hz / 115 Vac
Power supply voltage
Supply voltage of con-
trol unit
Absorbed power
Motor nominal power
Accessories max. cur-
rent (+24V)
BUS Accessories max.
current
Operating ambient tem-
perature
Fuses
F1 = self-resetting; F2 = T2A-250V
Function logics
Work time (time-out)
Varies according to learning
Pause time
Terminal board inputs
Open A, Open B, Stop, BUS (I/O)
Connector inputs
Motors 12Vdc, flashing lamp
24Vdc, power supply to acces-
Terminal board outputs
sories, electric lock, service light
Programmable func-
Logic (A, EP), Speed (depen-
tions
Learning functions
Different output values can be obtained on the
board supply terminals depending on the mains
voltage value. Before start-up always check if
the output voltage on the transformer secondary
winding is between 20 Vac and 26 Vac. Voltage
must be measured load free.

3.1. DESCRIPTION OF COMPONENTS

J1
POWER SUPPLY connector
J2
SERVICE LIGHT command terminal-board
J3
FLASHING LAMP terminal-board (24Vdc)
J4
ELECTRIC LOCK terminal-board
J5
COMMANDS terminal-board
J7
MOTOR 1 terminal-board (12Vdc)
J8
MOTOR 2 terminal-board (12Vdc)
J9
Rapid connection for RADIO MODULE
J10
BUS terminal-board
J11
BATTERY connector
SET UP push-button
SW1
SW2
SPEED push-button
SW3
LOGIC push-button
DS1
Programming Dip-switch
F1
Accessories protective fuse
F2
Fuses protecting transformers and motors
Signalling LEDs
LED
60 Hz
24 Vac nominal
4W
150 W x 2
250 mA
400 mA
-20°C - +55°C
EP , A
1 minute (fixed)
(max. 10 min.)
Power supply, battery, radio
module
contact (90 sec fixed)
ding on the motorization)
Pause time, leaf 2 delay at
closing

3.2. DESCRIPTION OF TERMINAL-BOARDS

Terminal
De-
and/or
scrip-
terminal-
tion
board
1
+24V
Power supply for accessories
2
GND
Negative
Device with NC contact which
3
J5
STOP
causes the automated system to
shut down
4
OPEN B Device with N.O contact (see
chap. FUNCTION LOGICS)
5
OPEN A
J10
Safety devices with BUS tech-
BUS
RED terminal
nology
J2
Service Light control output (con-
SERVICE
GREY ter-
nect a relay coil at 24Vdc-100mA
LIGHT
minal
max)
J3
ORANGE
LAMP
Flashing lamp 24Vdc - 15W
terminal
J4
Electric lock 12Vac or 24 Vdc (to
BLUE ter-
LOCK
be installed on leaf 1)
minal
J7
MOT1
Motor 1 (leaf 1)
J8
MOT2
Motor 2 (leaf 2)
Leaf 1 means the leaf which opens first during
the opening operation.
The service light control is active during the
entire gate opening or closing movement and
for the successive 90 seconds.

4. PROGRAMMING THE LOGIC

The function logic can be selected at any time by pressing
push-button SW3.
The selected logic is then displayed on LED LD7:
LED on = AUTOMATIC logic (A)
LED off = SEMIAUTOMATIC STEPPED logic (EP)

5. PROGRAMMING THE SPEED

The function logic can be adjusted at any time by pressing
push-button SW2.
The selected logic is then displayed on LED LD8:
LED on = HIGH speed
LED off = LOW speed

6. START-UP

6.1. LEDS CHECK

The following table shows that status of the LEDs in relation
to the status of the inputs (the closed at rest automated
system condition is shown in bold).
Check the status of the signalling LEDs as per table
below:
11
Device connected

Publicité

Table des Matières
loading

Table des Matières