Zodiac Jandy Pro Serie VS FloPro Manuel D'installation Et De Fonctionnement page 18

Masquer les pouces Voir aussi pour Jandy Pro Serie VS FloPro:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 18
English
symptom
Pump will not start.
Variable-Speed Controller LCD
is not displaying information
or
pump LEDs are not illuminated.
Controller displays "Pump not
connected".
Fault message appears on
controller display.
Jandy
Pro Series VS FloPro
®
No power to pump.
Make sure pump is properly connected to high voltage. LED on top of electronics
enclosure should be illuminated. See Section 3.2, Electrical Installation, in this
manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address setting.
Make sure that pump dip switches 3 and 4 are set properly for the installation.
Both should be OFF for use with Variable-Speed Controller or set to the proper
address when connected to an AquaLink
Section 3.3, VS-FHP Pump Dip Switch Settings, in this manual.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure
how to correct fault, contact technical support at 800.822.7933. In Canada, call
1-888-647-4004
Incorrect dip switch setting.
Make sure pump dip switches 1 and 2 are both ON if the controller is the JEP-R
and both are OFF if the ccontroller is a PDA or AquaLink RS. See Section 3.3,
VS-FHP Pump Dip Switch Settings, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address set.
Ensure pump dip switches 3 and 4 are set properly for the installation. Both
should be OFF for use with Variable-Speed Controller or set to the proper address
when connected to an AquaLink RS controller or an AquaLink PDA. See Section
3.3, VS-FHP Pump Dip Switch Settings, in this manual.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure
how to correct fault, contact technical support at 800.822.7933. In Canada, call
1-888-647-4004
|
Variable-Speed Pump
Installation & Operation Manual
possible Cause/solution
RS controller or an AquaLink PDA. See
®

Publicité

Table des Matières
loading

Table des Matières