Table 3.
recommended Wire sizes for Variable-speed pumps
rECoMMEndEd MiniMUM WirE siZE For Vs-Fhp pUMps*
distance from sub-panel
Model
VS-FHP 2.0
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
(NEC) or the Canadian Electrical Code (CSA) and local codes must be followed. Table shows minimum wire size and branch fuse
recommendations for typical installation.
3.2.4

installing the Controller

The VS-FHP pump can be operated by one (1) of
three (3) controllers: the variable-speed controller,
the AquaLink
RS controller (Rev O or later), or the
®
AquaLink PDA (Rev 4.0 or later). The FloPro variable-
speed pump communicates with the controllers via a
four-wire RS-485 interface.
If you need to cut the RS-485 cable to any custom length,
make sure to peel back and trim the ground shielded wire.
To install the variable-speed controller:

iMporTanT

The installer must TURN ON switches 1 and 2 at the
VS-FHP pump when connected to the variable-speed
controller.
noTE
The variable-speed controller part no. is JEP-R.
1.
Remove power from the VS-FHP pump by
disconnecting the high voltage lines or by
opening any breaker to which the VS-FHP pump
power is connected.
Warning
ElECTriCal shoCK haZard
Turn off all switches and the main breaker in the
VS-FHP pump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
2.
Remove the cover of the VS-FHP junction box
and feed the RS-485 cable into the fitting.
3.
Unplug the RS-485 connector from the VS-FHP.
4.
Attach the four (4) wires in the RS-485 cable
to the RS-485 connector. Match the wire colors
with the positions on the connector: 1- red, 2-
black, 3- yellow, and 4- green. See Figure 9.
Jandy
Pro Series VS FloPro
®
Branch Fuse aMps
Class: CC, g, h, J, K, rK, or T
230 VaC
20A
NOTE
Figure 9.
|
Variable-Speed Pump
Installation & Operation Manual
5.
Insert the RS-485 connector back into the VS-FHP.
6.
Slide dip switches 1 and 2 up, so they are in the
ON position, and slide switches 3 and 4 down, so
they are in the OFF position. See Figure 9.
7.
Connect the other end of the cable to the
controller. Match the colors of the wires with the
appropriate connector positions as follows: 1-
red, 2- black, 3- yellow, and 4- green.
8.
Restore power to the VS-FHP pump and verify
the operation of the controller.
9.
Refer to the Variable-Speed Controller Owner's
Manual, H0311200, to operate the pump.
Controller
(Rear View)
4-Position
DIP Switch
The VS-FHP pump comes with a
factory installed four-wire RS-485 cable.
Wiring Variable-speed Controller (JEp-r)
to Vs-Fhp pump
0-150 Feet
(0-45 metres)
Voltage
230 VaC
12
5 4 3 2 1
4 3 2 1
REMOTE CONTROL
RS485
Variable-Speed
Pump