Assembly; Maintenance; Air Filter; Air Relief Valve - Titan Tool Focus 500 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
GB

MAINTENANCE

with cleaning brush. (Fig. 12)
CAUTION! Never clean seals, diaphragm
and nozzle or air holes of the spray gun
with metal objects. The ventilation hose
and diaphragm are only solvent-resistant
to a limited extent. Do not immerse in
solvent, only wipe.
10. Remove the adjusting ring (fig. 13,1) carefully from
the union nut (2). Unscrew union nut (2), remove
air cap (3), nozzle (4) and nozzle seal (5).
Thoroughly clean all parts.
Take special care when cleaning the interstices on
the needle (Fig. 14)
11. Clean the outside of the container with a cloth soaked in
solvent or water.
12. Assemble the parts again (see "Assembly").
12.1

ASSEMBLY

ATTENTION! Follow the steps described
below exactly for assembly. Otherwise
the spray attachment may be damaged.
ATTENTION! Never operate the device if
the nozzle seal is missing, damaged or
incorrectly mounted. If the nozzle seal is
either missing, damaged or incorrectly
mounted liquids can enter the device and
increase the risk of an electric shock.
1. Push nozzle seal onto the needle so that the groove (slot)
points away from the spray attachment. (Fig. 15)
2. Place nozzle on the needle with recess downwards.
Attention: Position of needle must be congruent with
the nozzle aperture. (Fig. 16)
3. Place air cap on nozzle (pay attention to recesses in the air
cap). (Fig. 17)
4. Screw on union nut. (Fig. 18)
5. Snap the adjusting ring into the union nut. (Fig. 19)
Make sure that the two recesses on the adjusting ring
are engaged in the air cap clamps and that the lever for
adjusting the spray jet width is located on the pin.
6. Place the container seal from below on the feed tube and
slide it over the collar, while turning the container seal
slightly.
7. Screw the feed tube with the container seal into the body
of the gun.
In order to mount the gun more easily apply
lubricating grease (enclosed) liberally to the O-ring
at the spray attachment (Fig. 20).
20
13
MAINTENANCE
13.1

AIR FILTER

Attention! Never operate the device with
the air filter soiled or missing, as dirt could
be sucked up and affect the operation of
the device.
Always check the air filter before starting
work.
1. Unplug the power plug.
2. Release the air filter compartment
3. Clean (blow out) or replace the air filter (Fig. 22,1) depending
on the degree of soiling.
4. Push the clean air filter underneath the fixtures (fig. 22, 2)
on the left and right-hand sides (pay attention to the shape
of the air filter and compartment).
5. Reattach the cover of the air filter compartment and lock
.
13.2

AIR RELIEF VALVE

If paint has entered the ventilation hose, proceed
as follows:
1. Pull the ventilating hose (Fig. 23, 1) at the top from the
gun body. Screw off the valve cover (2). Remove the
diaphragm (3). Clean all the parts carefully.
CAUTION! The ventilation hose and
diaphragm are only solvent-resistant to a
limited extent. Do not immerse in solvent,
only wipe.
2. Place the diaphragm in the valve cover with the pin facing
forward (Also see the marking on the gun body).
3. Turn the body of the gun upside down and screw on the
valve cover from underneath.
4. Place the ventilating hose on the valve cover and on the
nipple at the gun body.
Focus 500
(fig. 21) and remove.

Publicité

Table des Matières
loading

Table des Matières