Qualitrol neoptix T/Guard 408 Manuel D'utilisation page 87

Table des Matières

Publicité

Enable
Enable Channel 1
channel
Enable Channel 2
Enable Channel 3
Enable Channel 4
Enable Channel 5
Enable Channel 6
Enable Channel 7
Enable Channel 8
Enable Channel 9
Enable Channel 10
Enable Channel 11
Enable Channel 12
Enable Channel 13
Enable Channel 14
Enable Channel 15
Enable Channel 16
Relay
Fail safe Relay 1
failsafe
Fail safe Relay 2
status
Fail safe Relay 3
Fail safe Relay 4
Fail safe Relay 5
Fail safe Relay 6
Fail safe Relay 7
Fail safe Relay 8
Calibration type
Unit
wtune
Analog out if error
TransLife™
TransLife Delta
TransLife Unity Temp
TransLife Years Of Life
TransLife Minutes Before
TransLife Minutes After
Temperature,
Channel 1 temperature
actual
Channel 2 temperature
Channel 3 temperature
Channel 4 temperature
Channel 5 temperature
Channel 6 temperature
Channel 7 temperature
Channel 8 temperature
Channel 9 temperature
Channel 10 temperature
Channel 11 temperature
Channel 12 temperature
Channel 13 temperature
Channel 14 temperature
Channel 15 temperature
Channel 16 temperature
Channel
Channel 1 status
status
Channel 2 status
Channel 3 status
Channel 4 status
Neoptix Canada LP ©
03
R/W
2301
03
R/W
2302
03
R/W
2303
03
R/W
2304
03
R/W
2305
03
R/W
2306
03
R/W
2307
03
R/W
2308
03
R/W
2309
03
R/W
2310
03
R/W
2311
03
R/W
2312
03
R/W
2313
03
R/W
2314
03
R/W
2315
03
R/W
2316
03
R/W
2401
03
R/W
2402
03
R/W
2403
03
R/W
2404
03
R/W
2405
03
R/W
2406
03
R/W
2407
03
R/W
2408
03
R/W
2501
03
R/W
2502
03
R/W
2504
03
R/W
2505
03
R
03
R
03
R
03
R
03
R
04
R
1
04
R
2
04
R
3
04
R
4
04
R
5
04
R
6
04
R
7
04
R
8
04
R
9
04
R
10
04
R
11
04
R
12
04
R
13
04
R
14
04
R
15
04
R
16
02
R
17
02
R
18
02
R
19
02
R
20
Document G1044FRr08
R
2301
0 = disable ; 1 = enable
R
2302
R
2303
R
2304
R
2305
R
2306
R
2307
R
2308
R
2309
R
2310
R
2311
R
2312
R
2313
R
2314
R
2315
R
2316
R
2401
0 = disable ; 1 = enable
R
2402
R
2403
R
2404
R
2405
R
2406
R
2407
R
2408
R
2501
0 = Neoptix ; 1 = Nortech Fibronic
R
2502
0 = °C ; 1 = °F
R
2504
0 = disable ; 1 = enable (optimize CCD time)
R
2505
0 = max if no signal ; 1 = min if no signal
R
2601
* 10 (Signed 16 bit integer)
R
2603
Temperature * 100, Signed 16 bit integer
R
2605
R
2607
R
2609
R
1
Temperature * 10, Signed 16 bit integer
R
2
R
3
R
4
R
5
R
6
R
7
R
8
R
9
R
10
R
11
R
12
R
13
R
14
R
15
R
16
R
17
R
17
0 = No signal *
R
18
R
19
R
20
1 = Probe detected
87