Visually check the machine for damage.
The machine must be checked before operation for any signs of damage that will affect the operation of the
machine. Particular notice must be taken to the mains cable, if the machine appears to be damaged it should
not be used, failure to do so may cause injury or death.
Check operation of the machine.
The machines operation must be checked to ensure that all components are working correctly.
Machine Brushes
Should be checked to make sure there is no abnormal wear present (this should be checked at least once a
week if used frequently). If the brush has worn more than 2/3 of the original length, the brushes should be
changed. Failure to do so may cause damage to the machine.
Magnetic base
Before every operation the magnetic base should be checked to make sure that there is no damage present.
An uneven magnet base will cause the magnet not to hold as efficiently and may cause injury to the
operator.
Adjustment of slide and bearing bracket alignment.
An essential requirement of the machine is that the slide can move in a smooth and controlled manner, free
of lateral movement and vibration.
This situation can be maintained by periodic adjustment of the slide and is accomplished in the following
manner:
1. Place the machine in an upright position and, by means of the capstan, raise the slide to its highest
position. Clean the brass gib strips and apply a small amount of light machine oil to the wear
surfaces.
2. Now lower the slide back to its lowest position. Bring the slide into the center of the dovetail slide
housing and loosen screws thus allowing free movement of the arbor support bracket.
3. Commencing with the middle screws, gently feed in all the screws until slight resistance is
encountered.
4. Operate the slide up and down a few times to test the movement and make any further necessary
adjustments. Try to ensure that all the screws are exerting a uniform pressure on the slide from top
to bottom. A perfectly adjusted slide will operate freely up and down without any sideways
movement.
5. Now raise the slide to its highest position. Slightly undo the arbor bearing bracket and, using fingers
only, tighten the screws.
6. Place the machine on a steel plate, connect to power supply and switch on the magnet. Start up the
motor. If the arbor is incorrectly aligned, the arbor support bracket will be seen to oscillate. Make
any necessary further adjustments to the bracket to ensure correct alignment of the spindle and
finally tighten the screws using a spanner. Lastly tighten the arbor bearing bracket.
Check machines grease.
The gearbox grease should be checked once a month to ensure all moving components are covered to
prevent wear. The grease should be changed at least once a year to ensure you gain the best from your
machine.
Check Armature of the machine.
This should be checked at least once a month to check that there are no visual signs of damage to the body
or to the commutator. Some signs of wear will be seen on the commutator over a period of time but this is
normal (this is the part that comes into contact with the brushes) however, if there are any signs of
abnormal damage the part should be replaced.