NATURAL GAS CONVERSION
Nominal Gas Consumption
Model NO.: BG179BAL
Gas Type
φ
Propane
φ
φ
Natural Gas
OPERATING INSTRUCTION:
1. To connect, push back socket sleeve (Fig. 1).
2. Insert plug and release sleeve (Fig. 2).
3. Push plug until sleeve snaps forward (Fig. 3). (Gas
will flow automatically. Failure to connect plug
properly to socket will inhibit gas flow to the
appliance.)
4. Test connection with ammonia-free soap and water
solution.
To disconnect
1. Pull sleeve back. Pull plug out of socket. (Gas is
automatically shut off.)
2. Close shut-off valve and replace dust caps on socket
and plug.
IMPORTANT:
Sticking the NG Label on the bottom panel.
Before operating your grill, after refueling, check carefully to be certain that all connections are
tight and there are no gas leaks.
1. Make 2-3 ounces of leak solution by mixing liquid dishwashing soap with water.
2. Make certain all control knobs are in the "OFF" position.
3. Brush small amounts of the leak solution on all the fittings and turn the gas on.
4. If bubbles appear, there is a leak. Proceed to step 5.
5. Turn the gas off and tighten all connections.
6. Go back to step 1 to retest the fittings.
7. If bubbles continue to appear, turn the gas off. Contact customer service.
IMPORTANT: Checking the GENERAL MAINTENANCE on Page 30 and LIGHTING on Page 28
after finished the conversion.
Conversion kits NO.: 839966-72 (For natural gas conversion use)
Orifice size
gas consumption
mm
12000 x 5
1.02 x 6pc
10000 x 1
0.93 x 1pc
12000 x 1
12000 x 5
1.45 x 7pc
12000 x 1
12000 x 1
Total gas
consumption
Btu/hr
Btu/hr
82000
84000
14
Gas pressure
kPa
2.74
1.74
Fig. 1