4
Value and parameter setting options
General
The settings of the ProLoop devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be
made using the corresponding method.
4.1
LCD display and controls
Standard display
Standard display
1-loop device
2-loop device
1
Basic functions 0 (see Table 4.14 for settings)
4.2
Parameters
1: Door and gate
2: Barrier
3: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
4: Direction logic
0: Loop 2
Relay response to malfunctions (see chapter 6 Troubleshooting):
A malfunction causes
1.Door/gate
the output relay to be
released. The alarm
systems
relay drops out.
Time functions 1, time unit 2 and time factor 3 (see Table 4.11a for settings)
4.3
The relay picks up when the
loop is activated and drops
out when the loop is exited.
Activation pulse:
The relay picks up when the
loop is activated and drops
out again after the time t.
Sensitivity 4 (see Table 4.11a for settings)
4.4
The sensitivity 5 (=Sensitivity) of the loop detector can be adapted in 9 stages: 51 = Lowest sensitivity, 59 = Highest sensitivity,
56 = Factory setting. The sensitivity setting depends on the frequencies (see chapter 4.6 Frequency).
Automatic Sensitivity Boost ASB 5 (see Table 4.11a for settings)
4.5
ASB (=Automatic Sensitivity Boost). ASB is required in order to be able to recognise trailer drawbars after activation.
Frequency 6 (see Table 4.11a for settings)
4.6
Four different frequencies F1, F2, F3, F4* can be set in order to avoid interference when using several loop detectors. These settings influence the
sensitivity (the sensitivity can be set in the range 1–7 for frequencies F1 to F3). F2 to F4 can be set for inductance < 150 µH and only F4 can be set for
inductance < 75 µH.
4.7
Direction logic7 (see Table 4.11a for settings)
The direction logic function can only be used with a 2-loop device. Direction logic must have been set in the basic function (see chapter 4.2). Detection
can be performed from:
Output 2 8 (see Table 4.11b for settings)
4.8
In a device with 2 outputs, output 2 can be either activated or deactivated. In ProLoop 11, output 2 can also be set as an alarm output.
Protection against power failure 9 (see Table 4.11a for settings)
4.9
Basic function 2 «Barrier systems» must be set for this function. This function is inactive by default (= factory setting).
P 1 = Car parks and automatic parking bollards: The sensitivity is restricted to 1–5 and the time function to h.
4.10
Changeover from operation to configuration mode
1- loop device
Display after start-up:
2- loop device
Display after start-up:
6
Control button
Control button
1
2
Mode
Sim1
Data
Sim2
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 1 to 2. Both loops must be
activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have re-
turned to a non-activated condition for another direction detection.
Loop 2 / output 2 can be deactivated in a 2-loop device.
2. Barrier
On delay:
The relay picks up after the
Loop
time t when the loop is acti-
Relay
vated and drops out when
the loop is exited.
On delay:
Loop
The relay picks up after the
time t when the loop is acti-
Relay
t t
vated and drops out when
the loop is exited.
Loop 1 to loop 2
From loop 2 zu loop 1
Touch the «Mode» button once
1
to change to configuration
mode
Touch the «Mode» button once
1
2
to change to configuration
mode
Mode
Explanation of the LCD display
Sim1
Loop 1, output 1
Function
1
Data
Example:
Sim2
Time
function set
A malfunction causes
3. Quiescent
the output relay to pick
up. The alarm relay
current
drops out.
t t
t t
from both directions
Mode
1
Sim1
Mode
1
Loop 1 is
Sim1
selected
Explanation of the LED
Red:
Green:
Loop 2,
Red & green: Configuration
2
output 2
Info
Flashing green: Loop activated
Flashing red:
Example:
Parameter «h»
Flashing
set
red + green:
A malfunction causes the
4. Direction logic
output relay to be
(2-loop device
released. The alarm relay
only)
drops out.
Off delay:
The relay picks up when the
Loop
loop is activated and drops
Relay
out after the time t when the
loop is exited.
Loop
Relay
Mode
2
Sim1
Start-up phase
Operation
Error
Simulation
A malfunction causes
the output relays to be
released. The alarm
relay drops out.
Loop
Relay
t t
Loop 2 is
selected
*Factory setting