Operating instructions
General
1
Safety instructions
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
2
Mechanical mounting in the switch cabinet
The ProLoop DIN variant is mounted on a 35 mm mounting rail acc. to EN 50 022 in the switch cabinet. In the ProLoop, the terminals are pluggable and
coded. The 11-pin version of the ProLoop is mounted onto a mounting rail base (BSF-11). This base is ordered and delivered separately as it is not included
in the scope of delivery.
3

Electrical connection

The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.
3.1
ProLoop DIN variant terminal connection diagram
A:
B:
Supply
Loop connection
voltage
1-channel device
connection
AC/DC
A1
AC/DC
A2
Output connection options (depending on the options ordered):
Relay assignment:
Output 1
1-loop device
Output 2
Alarm output
3.2
ProLoop 11 terminal connection diagram (BSF-11 base assignment)
Check the electrical connection (base assignment) when exchanging a loop detector from another manufacturer.
A:
B:
Supply
Loop connection
voltage
1-channel device
connection
AC/DC
A1
11
AC/DC
Output connection options (depending on the options ordered):
Relay assignment:
1-loop device
Output 1+2
C:
D:
Loop connection
Alarm output
2-channel device
connection
(optional)
L3
common
1
31
L3
L4
nc
32
L4
L5
2
34
no
L6
Output connection
diagram:
E
E, F
D, E, F
C:
D:
Loop connection
Relay connection
2-channel device
output 1
common
34
34
21
2
nc
24
A2
24
1
22
32
32
no
Output connection
diagram:
D, E
Loop detector for industrial doors and gates,
car parks and parking bollards
ProLoop loop detector DIN variant, mounting rail installation
ProLoop loop detector 11-pin, base mounting
LCD display
«Mode» button
«Data»-button
Terminals
Info LED
E:
F:
Relay connection
Relay connection
output 1
output 2
common
common
11
21
nc
nc
12
22
14
24
no
no
Relay assignment:
Output 1+2
2-loop device
Alarm output
E:
Relay connection
output 2
common
12
nc
31
14
no
Relay assignment:
2-loop device
Output 1+2
Output connection
diagram:
E, F
D, E, F
Output connection
diagram:
D, E
5