Install the Lower and Upper Vents

1. Using the following chart, decide which vents and rough opening (RO) sizes to use:
Certifi ed Vent
Upper Roof Exhaust Cap
Upper Roof Exhaust Vent
Large Vent (3 Louver)
Large Vent (10 Louver)
Small Vent
Universal Upper and Lower Vent
Install the vents exactly as described. Any other method will invalidate the warranty for the refrigerator.
2. Install the lower intake vent (See Art02337, Art02338, and Art02339):
The lower intake vent is also the service access opening for the components on
NOTICE
the rear of the refrigerator.
Make sure the bottom of the opening of the lower intake vent is even
!
WARNING
with or immediately below the fl oor level. This allows any leaking
propane gas to escape to the outside and not to collect at fl oor level.
- Make sure the bottom of the opening of the lower intake vent [9] is even with or immediately
below the fl oor level.
- Align the lower intake vent vertically below the coils [10] and the condenser [11] of the
refrigerator.
3. Install the upper exhaust vent:
Make sure that no sawdust, insulation, or other
!
CAUTION
construction debris is on the refrigerator or in the
enclosure. Debris can cause a combustion hazard and
prevent the refrigerator from operating correctly.
Tighten the screws of the upper roof exhaust cap to 10 inch-
NOTICE
pounds max. Also make sure that the air fl ow around the upper
roof exhaust cap is not blocked or decreased by other roof
mounted features such as a luggage carrier, an air conditioner, a
solar panel, etc.
- If the design of the vehicle allows, install the roof exhaust vent [12] directly
above the condenser [11] of the refrigerator (See Art02337):
- Install a baffl e [13] to prevent stagnant hot air in the area [14] above the
refrigerator.
Installation and Owner's Manual 18
P/N
RO Height
622293
N/A
616319
24 in.
621156xx
13 ¾ in.
690136xx
9 13/16 in.
633588xx
6 5/32 in.
620505xx
6 3/16 in.
RO Width
Overall Vent Size
N/A
10½ in. x 33 in.
5 1/4 in.
7 7/16 in. x 26 7/23 in.
21 ½ in.
16 15/32 in. x 24 7/32 in.
19 5/16 in.
11 1/16 in. x 21 in.
17¾ in.
7 11/32 in. X 19 1/32 in.
17 13/16 in.
8 5/32 in. X 19 5/8 in.
14
13
10
27
11
10
9
Art02339
12
19
16
11
19
16
17
9
Art02337