10. Maintenance and Care

The belt needs no maintenance. Spare parts are available for carrying out
repairs (see chapter 13).

11. Malfunctions

The following table describes malfunctions, their causes and correspond-
ing remedies.
If it is not possible to remedy the malfunctions with the described correc-
tive action, send the breathing protection apparatus to the SATA customer
service department. (For address see chapter 12).
Malfunction
Buckle does not close

12. After Sales Service

For accessories, spare parts and technical support, contact your SATA
dealer.

13. Spare Parts

Art.
No.
208439 Textile strap with clasp
[3-1]
208447 Hip padding
[3-2]
208462 Adapter plate
[3-3]

14. EU Declaration of Conformity

We hereby declare that, in its design and construction as well as in the
version as it is produced and distributed by us, the product described in
the following corresponds to the fundamental health and safety require-
ments of Directive (EU) 2016/425 as well as the fundamental safety re-
quirements of EC-Directive 2014/34/EU including any changes applicable
at the time of this declaration.
This Declaration loses its validity in case of any alteration to the device
that has not been approved by us.
The manufacturer bears the sole responsibility for the issuance of this
declaration of conformity.
Manufacturer
SATA GmbH & Co. KG
Domertalstrasse 20
Operating instructions SATA air regulator belt
Cause
Buckle severely soiled
Description

Corrective action

Clean buckle
Number