To be integrated with a complete reading of the technical specifi cations
Positioning and installation
Commissioning done by an approved CAT that issued the guarantee
Air vent in the room
Only the boiler-stove outlet passes through the smoke channel/chimney fl ue
Features of the smoke channel (stretch of duct connecting the boiler-stove to the fl ue/chimney):
a maximum of 3 curves
a maximum of 2 horizontal metres
The exhaust pipes are made of suitable material (recommended: stainless steel)
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
The heating capacity has been appropriately assessed considering radiator effi ciency:
The hydraulic system has been declared to be compliant with the Ministerial Decree 37 ex Law No. 46/90 by a qualifi ed
technician.
Use
Good quality, dry wood pellets are used (diameter 6 mm) (maximum permissible humidity 8%).
The chimney pot and ash compartment are clean and well positioned.
The cleaning rods are moved every day.
The exchanger tubes and internal parts of the hearth are clean.
The smoke extract duct is clean.
The bleeding process has been applied to the hydraulic system.
The pressure (shown on the pressure gauge) is at least 1,5 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
TELEP HONE COMBINER FOR RE MOTE IGNITION
The boiler-stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the
boiler-stove via the optional cable (code 640560).
GlassKamin
Used for cleaning the ceramic glass
CHECK LIST
OPTIONAL

CLEANING ACCESSORIES

- 41
-
Ash vacuum cleaner
Used for cleaning the hearth