6. ACTIVATING THE OUTPUTS

The VGSM-120 has 3 terminals (the T1, T2 and T3 terminals) that can be programmable as Inputs or/and
Output: this terminals are programmed as Outputs by default. The Open-Collector Outputs can be activated
automatically (when certain pre-programmed events occur) or remotely, through SMS trasmission or caller
identification from a number programmed previously.

Activating/Deactivating Automatic Outputs

The T1,T2 and T3 Open Collector outputs can be activated automatically by the following events:
Land line trouble (line down);
GSM Network trouble (Limited/No Service);
Supervision message missing;
Internal event communication failed (FTC).
Note:
Once an OC output has been automatically activated, it will only return to standby mode when all
the causes of activation have been cleared, except if there is a Failure To Communicate an
internal event (FTC), in which case it returns to standby mode after the ON Time has expired.

Remote Activation and Deactivation of the Outputs

CAUTION! The GSM connection must be established before the outputs can be activated/deactivated
remotely.
We recommend the device is programmed with the Black list enabled (Options->Dial Options)
and White list disabled (Phonebook->White list) for the numbers you wish to use for this function.
The number used to activate the outputs via Caller Identification must be visible.
The Open Collector outputs can be set as Bistable (activation and deactivation takes place by means of 2
separate commands) or Monostable (the output remains active for the ON time and returns to standby mode
when this period has elapsed or when it is deactivated by means the specific SMS). Moreover, every output
can be programmed to provide a confirmation signal (an SMS programmed previously if output
activation/deactivation is performed via SMS, or a confirmation ring if output activation/deactiva- tion is
performed via caller identification).
Note:
For further information on the terms "Control string" and "User code" used in the following
sections, please refer to the "I/O" and "Options->Codes" sections of the "PROGRAMMING VIA
PC" chapter.

Bistable outputs

Open collector outputs set as bistable can be activated in 2 ways:
1.
By sending an SMS consisting of the User code between two # characters, the Control string
(Control String cannot have initial blank spaces) and the characters "=ON#", as follows:
2.
Through caller identification: in this case the output is activated at "cost-free" as the Communicator,
after identifying the caller, rejects the call and activates the output.
Note:
A bistable OC output can ONLY be deactivated by sending an SMS message consisting of the
User code between two # characters, the Control string and the characters "=OFF#", as follows:
Note:
The default User code is '0001'; if you wish to change it, please refer to the section "Remote
programming by SMS message->Changing the User code".

Monostable Outputs

OC outputs set as Monostable may be activated in 2 ways, through Caller Identification and via SMS.
D-305708 VGSM-120 Installation Instructions
#User code#String=ON#
#User code#String=OFF# (example: #9876#HOUSELIGHT=OFF#)
(example: #9876#HOUSELIGHT=ON#)