Parameter's Menu - Watts BT-D Mode D'emploi

Masquer les pouces Voir aussi pour BT-D:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

Parameter's menu

5
Your thermostat has a parameter's menu, in order to enter in this menu, press and maintain the edition key ( ) during
5sec. Then parameter menu will appear and first parameter screen will be displayed:
Now you can select a parameter which must be adjusted with the navigation keys (◄) or (►), once the parameter
chosen, toggle the value with the (OK) key, modify it with (-) or (+) and confirm your adjustment with (OK).
To leave the parameter menu, choose the parameter « End » and press (OK).
01
dEG: Unit of the temperatures displayed
°C Celsius
°F Fahrenheit
04
AirC: Calibration of the internal probe
The calibration must be done after 1 day working with the same setting temperature in accordance with
the following description:
Put a thermometer in the room at 1.5M distance from the floor (like the thermostat) and check the real
temperature in the room after 1 hour.
When you enter on the calibration parameter "no" is displayed on the right to indicate no calibration has
made.
To enter the value shown on the thermometer, use the (-) or (+) keys to enter the real value. Then, press
(Ok) to confirm.
The message "Yes" should be displayed; the value will be stored in the internal memory.
If you need to erase a calibration press on the escape key ( ).
The old value will be erased and the message "no" will be displayed.
* Pay attention:
Only the heating element driven by the thermostat must be used during the complete step of the
calibration.
05
OutC , AMbC , FlrC: Calibration of the external wired probe
Same calibration method as described in parameter
"04 AirC" above.
06
HG: Anti-freeze temperature used in Holiday mode
Default value 10°C.
Use the (-) or (+) keys to change the anti-freeze setting temperature. Then press (Ok) to confirm.
08
Clr ALL: Reset to Factory setting
Press and maintain (Ok) key during 10s to reset Set points temperatures and user parameters in this
menu to factory default settings. User programs will also be resetted.
* Pay attention:
Ensure you that you have all necessary elements to re-setup your installation before to use this function.
09
Software version
VErS ___
End: Exit the parameter's menu
10
Press (OK) key to exit installation parameter menu and return to normal operation.
Default value & other possibilities
10

Publicité