Télécharger Imprimer la page

Table Des Matières; Safety Precautions; Packaging Content; Technical Specifications - König Electronic SEC-SA200 Mode D'emploi

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Interconnectable Optical Smoke Alarm
Table of contents:
• Introduction
(p. 2)

• Safety precautions

(p. 2)

• Packaging content

(p. 2)

• Technical specifications

(p. 7)
(p. 7)
(p. 7)
Introduction:
This battery operated optical smoke alarm sends out a signal through radio frequency to activate other
installed SEC-SA200's in case smoke is detected. When installing multiple SEC-SA200's, the smoke alarm
that detects smoke will automatically activate all other SEC-SA200's to give an early warning audible alarm.
This provides extra time to leave the house. Equipped with a learn button and a test button for periodic
testing.
A smoke alarm has a limited life and should always be replaced 10 years after the date of purchase. Write
the purchase date on this manual for future reference.
The smoke alarm complies with the EN14604 standard of the Construction Products Directive.
We recommend that you read this manual before you install the smoke alarm
Keep this manual in a safe place for future reference
Safety precautions:
Do not expose the product to water or moisture
Do not paint over the smoke alarm
Packaging content:
• 1x Smoke alarm
• 1x 9 V battery
• 3 x 1.5 V AA batteries
• 1x Mounting material
• 1x Manual
Technical specifications:
• Radio frequency: 433.92 MHz
• Battery: 1x 9 V DC, 3x 1.5 V AA
• Alarm: >85 db (3m)
• Maximum number to connect: unlimited
• Maximum range: 40 metres
• Test button: yes
• Learn button: yes
• Low battery alert: yes
• Operating temperature: -10 °C ~ + 40 °C
ENGLISH
(p. 2)
(p. 5)
2

Publicité

loading