3.7 Testing Diodes

To avoid electrical shock and damage the meter when
measuring diode in a circuit, make sure the power to the circuit
is turned off and all capacitors are discharged.
1. Turn the rotary switch to
make sure power is disconnected from the circuit to
be measured.
2. Press the yellow button twice.
3. Connect the red test probe to the anode side and black test lead to the cathode
side of the diode being tested.
4. Read the forward bias voltage value on the display.
5. If the polarity of the test leads is reversed with diode polarity or forward bias
voltage is above 3V, the display reading shows OL.
This can be used to distinguish the anode and cathode sides of the diode.