1. USER GUIDE

GAS DETECTOR
Installation Instructions
Recommended Installation Locations
Mount the detector on the wall or cabinet about 30cm above the ground for LPG or, about
30cm below the ceiling for carbon monoxide gas and natural gas use.
The ventilation hole should be installed facing downwards.
General limitations
Install the detector securely to avoid impact and drop.
Prevent dust and oil from entering the detector as this could block the ventilation slots and
cause the detector to malfunction.
Do no install the gas detector near hot, humid and oily sources.
Do not install the gas detector near windows or fans where a gas leak can be quickly
dispersed
Using the Gas detector
Plug the flying lead of the detector into a 230V/50Hz wall socket.
The equipment needs 3--5 minutes for the sensor to begin functioning. The green LED will light
up in normal mode.
Alarm operation
When the Gas detector detects an ignitable gas, three short alarm beeps will sound at
intervals until the ignitable gas has disappeared.
If the detector is malfunctioning, a single alarm beep will sound continuously.
The red LED will flash in conjunction with the alarm beep. I.e., the red LED will flash during a
gas alarm and a low battery mode alarm.
Testing the Detector
To ensure the correct functioning of the detector, it is recommended to test the detector on
a monthly basis.
The detector can either be checked by using the 'test' button on the side of the detector.
Technical Specifications
Power Source :
Sensitivity :
Power Consumption :
Operating Temperature :
Ambient Humidity :
Horn Level :
Weight :
Type Of Gas Sensed :
10-9-2008
220V AC
10%LEL
1.7W
-10° ~ 50°C
Less than 95% RH
85 Decibels
270g
+ LPG (Butane, Propane)used in normal and mini gas
bottles
+ Gas from piping system (city gas) and natural gas
(Methane)
3