Electrodes Adjustment; Pump Pressure - Riello RG1RK Instructions Pour L'installation, L'utilisation Et L'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

B
Fig. 11
Remove nozzle-holder assembly (1) after
loosing screws (2) and nut (3), remove the
small cables (4) from the control box, the
photoresistance (6) and the socket (10).
Withdraw the small cables (4) from the elec-
trodes, remove the diffuser disc-holder assem-
bly (11) from the nozzle-holder assembly (1)
after loosing screw (3, fig. 12).
Screw the nozzle (12) correctly and tight-
en it as shown in figure.
ATTENTION
During the reassembly of the nozzle-holder
assembly screw the nut (3) as shown in the
figure below.
TIGHTEN WITHOUT MOVING
BACKWARDS TO THE END

4.3 ELECTRODES ADJUSTMENT

WARNING
Lean the diffuser disc-holder as-
sembly (1) on the nozzle-holder (2)
and lock it by screw (3).
For prospective adjustments of
t h e e l e c t r o d e s a s s e m b l y ( 4 ) ,
loosen screw (5).
To have access to the electrodes
carry out operation as described in
ch a p t er " 4 . 2 R E C O M M E N D E D
NOZZLES" (page 6).

4.4 PUMP PRESSURE

The pump leaves the factory set at 12 bar.
To change it act on pump pressure adjust screw (4, fig. 5, page 4).
2302
D5684
3
(see fig. 12)
Fig. 12
B
Fig. 11
0
4.5
– 0.5 mm
2
4
3
1
D5343
7
GB
S7196
WARNING
MEASURES
MUST BE RESPECTED
2 – 2.5
mm
5
5.5 ±
0.3 mm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

362 t13736250

Table des Matières