MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

EN
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER
THE STEEL STUD FRAMING KITS WITH CEMENT BOARD PROVIDED MUST BE INSTALLED.
IMPORTANT: The HD81 requires a minimum inside enclosure height of 84" (2134mm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the air.
84"
2132mm *
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
FIREPLACE
OPENING
* Refer to "VENTING" section.
** NOTE: Within the appliance enclosure a 3" (76mm) clearance between the vertical vent run and the combustible ma-
terials on the front facing of the enclosure is required. Similarly, a 14" (356mm) clearance to combustible materials from
the top of the horizontal vent run is required. All other clearances within the enclosure, including where the vent pipe
exits the enclosure are subject to 2" (51mm) for horizontal and 1" (25mm) for vertical.
W415-1406 / 11.19.14
THE APPLIANCE OPENING.
COMBUSTIBLE
MATERIAL
50 1/2"
1283mm
MINIMUM
STEEL STUD
FRAMING
33 1/2"
851mm
MINIMUM
WARNING
!
RISK OF FIRE!
TOP OF ENCLOSURE
14"
356mm
MINIMUM **
7 5/8"
194mm
MINIMUM
BRICK
2" 51mm
0" (0mm) IF NON-
COMBUSTIBLE FINISHING
IS USED SUCH AS BRICK
AND STONE
2" 51mm
64 1/4"
1632mm
MINIMUM
PLUS RISE *