TECHNICAL DATA
THERMIC CAPACITY
OPERATION
NOx EMMISION
MOTOR
ABSORBED ELECTRICAL POWER*
E
N
LINE FUSE
G
IGNITION TRANSFORMER
L
VOLTAGE
I
PROTECTION RATING
S
FLAME DETECTOR
H
NOISE**
WEIGHT
Natural Gas (G 20)
FLOW RATE
PRESSURE
*)
Total absorption at start with ignition transformer on.
**) Noise levels measured by the manufacturer in the laboratory with burner running on test boiler, at maximum nominal thermal output.

STANDARD ACCESSORIES

BURNER FIXING FLANGE
ISOLATING GASKET
STUD BOLTS
EXAGONAL NUTS
FLAT WASHERS
TBG
50LX PN
80LX PN
MAX kW
550
MIN kW
110
mg/kWh < 80 (Classe III EN 676)
kW
0,55
r.p.m.
2800
kW
0,66
A 400 V
6
dBA
72
kg
76
MAX
m³n/h
55,3
MIN
m³n/h
11
MAX
mbar
TBG
TBG
50LX PN
80LX PN
2
2
1
1
N° 4
N° 4
M 12
M 12
N° 4
N° 4
M 12
M 12
N° 4
N° 4
Ø 12
Ø 12
22 / 75
0006081327_200807
TBG
TBG
TBG
110LX PN
140LX PN
800
1200
1450
130
180
200
modulante
Two-stage progressive
1,1
1,5
2,2
2800
2800
2800
1,20
1,60
2,40
6
10
10
26 kV - 40 mA – 230 V / 50 Hz
3N ~ 400 V ±10%- 50 Hz
IP 44
SONDA DI IONIZZAZIONE
73
75,5
79
78
87
91
80,5
120,7
145,8
13,1
18,1
20,1
500
TBG
TBG
110LX PN
140LX PN
2
2
1
1
N° 4
N° 4
M 12
M 12
N°4
N° 4
M 12
M 12
N° 4
N° 4
Ø 12
Ø 12
TBG
200LX PN
1900
475
3
2800
3,20
16
85
94
191,1
47,8
TBG
200LX PN
2
1
N° 4
M 12
N°4
M 12
N° 4
Ø 12